Axial stress in a fully restrained (buried) pipeline from temperature and internal pressure (Poisson effect), and the force on the anchor at its end.

Inputs

Examples: Illustrative 12 in pipeline at 70 bar, +40 KWater main 600 mm at 16 bar, +15 KHot oil line, +80 K

Accepted: 10 to 3,000 mm
Accepted: 1 to 100 mm
Accepted: 0 to 500 bar
Accepted: -100 to 300 K
Accepted: 1 to 400 GPa
Accepted: 1 to 30 µm/(m·K)
Accepted: 0.1 to 0.5

Results

A long buried pipeline is held by the soil and cannot change length. Heating would lengthen it by αΔT and pressure would shorten it by the Poisson effect of the hoop stress (ν σ_h/E), so the axial stress is σ_L = ν σ_h − EαΔT. Where the pipe leaves the ground or turns, the anchor must hold the difference between the restrained pipe and a free pipe: the thermal force A_s EαΔT plus the pressure end force p A_i less the Poisson part ν σ_h A_s. The hoop stress uses the thin-wall formula on the inside diameter.

Hoop stress61.962MPa
Axial stress in the restrained section (negative = compression)-173.41MPa
Thermal part of the anchor force1,040.7kN
Pressure part (end cap minus Poisson)60.658kN
Anchor force at the end of the restrained section1,101.3kN
Steel cross-section5,420.3mm²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 12 in pipeline at 70 bar, +40 K. The inputs, in the units selected above:

InputValue
Pipe outside diameter323.90 mm
Wall thickness9.5300 mm
Internal pressure (gauge)70.000 bar
Temperature rise above the installation temperature40.000 K
Elastic modulus203.00 GPa
Thermal expansion coefficient11.700 µm/(m·K)
Poisson's ratio0.30000 -

Applying the formula below gives:

ResultValue
Hoop stress111.96 MPa
Axial stress in the restrained section (negative = compression)-61.417 MPa
Thermal part of the anchor force894.18 kN
Pressure part (end cap minus Poisson)194.78 kN
Anchor force at the end of the restrained section1,089.0 kN
Steel cross-section9,412.0 mm²

Open this example in the calculator and change any input.

Formula

\(\sigma_h = \frac{p D_i}{2t}, \quad \sigma_L = \nu\sigma_h - E\alpha\Delta T, \quad F = A_s E\alpha\Delta T + pA_i - \nu\sigma_h A_s\)

Variables

Symbol Meaning SI unit
\(D_o\) Pipe outside diameter m
\(t\) Wall thickness m
\(p\) Internal pressure (gauge) Pa
\(\Delta T\) Temperature rise above the installation temperature K
\(E\) Elastic modulus Pa
\(\alpha\) Thermal expansion coefficient 1/K
\(\nu\) Poisson's ratio -
\(\sigma_h\) Hoop stress Pa
\(\sigma_L\) Axial stress in the restrained section (negative = compression) Pa
\(F_T\) Thermal part of the anchor force N
\(F_p\) Pressure part (end cap minus Poisson) N
\(F\) Anchor force at the end of the restrained section N
\(A_s\) Steel cross-section m²

Method and standards

Restrained pipe.

Where it is used

  • Anchor blocks of buried pipelines.
  • Checking pipeline axial stress.

Common mistakes

  • Forgetting the Poisson effect.
  • Applying the restrained formula to an above-ground flexible pipe.

Assumptions and limits

  • Fully restrained straight pipe; linear elastic; thin-wall hoop stress.

References

  • Axial stress of a fully restrained pipe: σ_L = ν σ_h − EαΔT (thin-wall hoop stress)

Questions and answers

Why does pressure reduce the anchor force?

Pressure swells the pipe, which by Poisson's effect shortens it: in a restrained pipe this gives axial tension that partly offsets thermal compression.

How big is the thermal force?

About 2.4 MPa per kelvin of axial stress in carbon steel: 40 K gives about 95 MPa.

What do the defaults represent?

An illustrative 12 in (323.9 mm × 9.53 mm) steel pipeline at 70 bar(g), 40 K above its laying temperature.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.