FireCADCalc

Buried Pipe Trench Load (Marston Formula)

Earth load on a pipe laid in a trench by the Marston formula, for rigid and flexible pipes, compared with the weight of the soil prism above the pipe.

Inputs

Examples: Illustrative 600 mm pipe, 3 m sand and gravelDeep clay trenchShallow granular

Accepted: 10 to 25 kN/m³
Accepted: 0.1 to 30 m
Accepted: 0.2 to 10 m
Accepted: 50 to 5,000 mm

Results

Backfill settling in a trench is held up by friction on the trench walls, so a pipe carries less than the full weight of soil above the trench: W = C_d w B_d², with C_d = (1 − e^(−2Kμ′H/B_d))/(2Kμ′). A rigid pipe takes the load over the trench width; a flexible pipe, with well-compacted soil at its sides sharing the load, takes it over its own diameter. Keep the trench narrow at the top of the pipe: the load grows with the square of the trench width up to the embankment (positive projection) condition.

Load coefficient1.7023
Load on a rigid pipe46.085kN/m
Load on a flexible pipe (soil well compacted at the sides)23.043kN/m
Weight of the soil prism over the pipe33.840kN/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 600 mm pipe, 3 m sand and gravel. The inputs, in the units selected above:

InputValue
Unit weight of the backfill18.800 kN/m³
Cover depth to the top of the pipe3.0000 m
Trench width at the top of the pipe1.2000 m
Pipe outside diameter600.00 mm
Backfill type (product of Rankine ratio and friction)Sand and gravel (0.165)

Applying the formula below gives:

ResultValue
Load coefficient1.7023
Load on a rigid pipe46.085 kN/m
Load on a flexible pipe (soil well compacted at the sides)23.043 kN/m
Weight of the soil prism over the pipe33.840 kN/m

Open this example in the calculator and change any input.

Formula

\(W = C_d\,w\,B_d^2, \quad C_d = \frac{1 - e^{-2K\mu' H/B_d}}{2K\mu'}\)

Variables

Symbol Meaning SI unit
\(w\) Unit weight of the backfill N/m³
\(H\) Cover depth to the top of the pipe m
\(B_d\) Trench width at the top of the pipe m
\(B_c\) Pipe outside diameter m
\(K\mu'\) Backfill type (product of Rankine ratio and friction) -
\(C_d\) Load coefficient -
\(W_r\) Load on a rigid pipe N/m
\(W_f\) Load on a flexible pipe (soil well compacted at the sides) N/m
\(W_p\) Weight of the soil prism over the pipe N/m

Method and standards

Marston load.

Where it is used

  • Design of buried water, sewer and cooling-water pipes.
  • Checking trench width for a given pipe.

Common mistakes

  • Using the trench width at the surface instead of at the top of the pipe.
  • Using the trench formula for an embankment installation.

Assumptions and limits

  • Trench condition; no live load or surcharge; settled backfill.

References

  • Marston–Spangler trench-condition load theory

Questions and answers

Why is the load less than the soil prism weight?

The settling backfill hangs on the trench walls through friction, carrying part of its own weight.

Why keep the trench narrow?

The load on a rigid pipe grows with the square of the trench width at the top of the pipe.

What do the defaults represent?

An illustrative 600 mm pipe under 3 m of sand and gravel backfill (18.8 kN/m³) in a 1.2 m trench.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Moody and Spangler: Marston load theory for buried conduits (Spangler and Handy, Soil Engineering, 4th ed., Harper and Row, 1982)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.