Pipeline Hydrotest: Pressure Change per Degree of Water Temperature

Pressure change of a water-filled, closed, restrained pipeline per kelvin of water temperature change during a hydrostatic test, from the water and steel properties.

IAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative 20 in pipeline at 100 bar, 15 CWarm water 25 C, 10 inCold water 6 C

Accepted: 10 to 3,000 mm
Accepted: 1 to 100 mm
Accepted: 1 to 300 bar
Accepted: 1 to 50 °C
Accepted: 1 to 400 GPa
Accepted: 0.1 to 0.5
Accepted: 1 to 30 µm/(m·K)
Accepted: -30 to 30 K

Results

In a closed, full pipe the water tries to expand by its volumetric expansion B per kelvin while the steel bore grows by about 2A (the pipe is restrained along its length). The difference is taken up by compressing the water (C) and stretching the pipe wall (D(1 − ν²)/(E t)), giving Δp/ΔT = (B − 2A)/[D(1 − ν²)/(E t) + C]. Cold water expands little, so near 4 °C the pressure barely changes and below it may even fall as the water warms; at 15–20 °C a change of 1 K moves the pressure by a few bar. Record the water temperature during a hold test and correct for it before judging a leak. Water properties are from IAPWS-IF97 at the test pressure.

Volumetric thermal expansion of the water57.249µm/(m·K)
Compressibility of the water4.7710e-041/MPa
Pressure change per kelvin0.49191bar
Pressure change for the temperature change1.4757bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 20 in pipeline at 100 bar, 15 C. The inputs, in the units selected above:

InputValue
Pipe outside diameter508.00 mm
Wall thickness12.700 mm
Test pressure (gauge)100.00 bar
Water temperature15.000 °C
Elastic modulus of steel207.00 GPa
Poisson's ratio0.30000 -
Linear thermal expansion of steel11.700 µm/(m·K)
Temperature change during the test1.0000 K

Applying the formula below gives:

ResultValue
Volumetric thermal expansion of the water169.86 µm/(m·K)
Compressibility of the water4.5530e-04 1/MPa
Pressure change per kelvin2.3206 bar
Pressure change for the temperature change2.3206 bar

Open this example in the calculator and change any input.

Formula

\(\frac{\Delta p}{\Delta T} = \frac{B - 2A}{\dfrac{D(1-\nu^2)}{E\,t} + C}\)

Variables

Symbol Meaning SI unit
\(D\) Pipe outside diameter m
\(t\) Wall thickness m
\(p\) Test pressure (gauge) Pa
\(T_w\) Water temperature K
\(E\) Elastic modulus of steel Pa
\(\nu\) Poisson's ratio -
\(A\) Linear thermal expansion of steel 1/K
\(\Delta T\) Temperature change during the test K
\(B\) Volumetric thermal expansion of the water 1/K
\(C\) Compressibility of the water 1/Pa
\(\Delta p/\Delta T\) Pressure change per kelvin Pa
\(\Delta p\) Pressure change for the temperature change Pa

Method and standards

Hydrotest temperature correction.

Where it is used

  • Pipeline hydrostatic test records.
  • Judging pressure loss in hold tests.

Common mistakes

  • Ignoring water temperature during a long hold.
  • Using the steel's volumetric expansion 3A for a restrained pipeline.

Assumptions and limits

  • Long restrained pipe full of air-free water; thin wall.

References

  • Pressure–temperature relation of a restrained water-filled pipe (B − 2A)/(D(1 − ν²)/Et + C)
  • IAPWS-IF97 water density
  • expansion and compressibility

Questions and answers

Why did my hydrotest pressure drop overnight without a leak?

The water cooled: at about 15 °C a 1 K drop lowers the pressure by roughly 2 bar in a 20 in, 12.7 mm pipe.

Why does the effect vanish near 4 °C?

Water has its greatest density at about 4 °C, so its expansion coefficient is nearly zero there.

What do the defaults represent?

An illustrative 20 in (508 × 12.7 mm) pipeline tested at 100 bar(g) with water at 15 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators