FireCADCalc

Reynolds Number and Flow Regime in a Pipe

Reynolds number from velocity, diameter, density and viscosity, with the flow regime (laminar, transition, turbulent) and the Darcy friction factor (Colebrook).

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserPump

Inputs

Examples: Water 2 m/s in DN100 (102.3 mm), steelFurnace oil 0.5 m/s, 52.5 mm, 950 kg/m³, 200 cPTransition: oil 1 m/s, 40.9 mm, 870, 15 cP

Commercial steel about 0.045 mm; drawn tubing 0.0015 mm; cast iron 0.26 mm.

Results

Reynolds number124.69
Regime: 0 laminar, 1 transition, 2 turbulent0
Darcy friction factor0.51328
Kinematic viscosity2.1053e-04m²/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water 2 m/s in DN100 (102.3 mm), steel. The inputs, in the units selected above:

InputValue
Mean velocity2.0000 m/s
Inside diameter (or hydraulic diameter)102.30 mm
Fluid density998.20 kg/m³
Dynamic viscosity1.0020 cP
Absolute roughness of the wall0.045000 mm

Applying the formula below gives:

ResultValue
Reynolds number203,824
Regime: 0 laminar, 1 transition, 2 turbulent2.0000
Darcy friction factor0.018472
Kinematic viscosity1.0038e-06 m²/s

Open this example in the calculator and change any input.

Formula

\(Re = \frac{\rho\,v\,D}{\mu} \qquad \nu = \frac{\mu}{\rho} \qquad f = \frac{64}{Re}\ (Re < 2300) \qquad \frac{1}{\sqrt f} = -2\log_{10}\left(\frac{\epsilon/D}{3.7} + \frac{2.51}{Re\sqrt f}\right)\)

Variables

Symbol Meaning SI unit
\(v\) mean velocity m/s
\(D\) inside diameter m
\(\rho\) density kg/m³
\(\mu\) dynamic viscosity Pa·s
\(\epsilon\) absolute roughness m
\(Re\) Reynolds number –
\(\text{regime}\) 0 laminar, 1 transition, 2 turbulent –
\(f\) Darcy friction factor –
\(\nu\) kinematic viscosity m²/s

Method and standards

Reynolds number by definition; Darcy friction factor 64/Re in laminar flow and Colebrook–White above (used also in transition, conservatively).

Where it is used

  • Pipe and duct pressure drop.
  • Heat transfer correlations.
  • Choosing flowmeters.

Common mistakes

  • Using kinematic viscosity as dynamic.
  • Using nominal instead of inside diameter.
  • Applying 64/Re in turbulent flow.

Assumptions and limits

  • Full circular pipe; Newtonian fluid.

References

  • Colebrook–White (1939); Moody (1944)

Questions and answers

What is Re for water at 2 m/s in DN100?

About 204 000: turbulent, with a Darcy friction factor of 0.0185 in commercial steel.

Where does laminar flow end?

Around Re 2300; above 4000 flow is turbulent; between is transition.

Darcy or Fanning?

This is the Darcy factor, four times the Fanning factor.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.