Worked example
Example: Water 2 m/s in DN100 (102.3 mm), steel. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean velocity | 2.0000 m/s |
| Inside diameter (or hydraulic diameter) | 102.30 mm |
| Fluid density | 998.20 kg/m³ |
| Dynamic viscosity | 1.0020 cP |
| Absolute roughness of the wall | 0.045000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reynolds number | 203,824 |
| Regime: 0 laminar, 1 transition, 2 turbulent | 2.0000 |
| Darcy friction factor | 0.018472 |
| Kinematic viscosity | 1.0038e-06 m²/s |
Open this example in the calculator and change any input.
Formula
\(Re = \frac{\rho\,v\,D}{\mu} \qquad \nu = \frac{\mu}{\rho} \qquad f = \frac{64}{Re}\ (Re < 2300) \qquad \frac{1}{\sqrt f} = -2\log_{10}\left(\frac{\epsilon/D}{3.7} + \frac{2.51}{Re\sqrt f}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(v\) | mean velocity | m/s |
| \(D\) | inside diameter | m |
| \(\rho\) | density | kg/m³ |
| \(\mu\) | dynamic viscosity | Pa·s |
| \(\epsilon\) | absolute roughness | m |
| \(Re\) | Reynolds number | – |
| \(\text{regime}\) | 0 laminar, 1 transition, 2 turbulent | – |
| \(f\) | Darcy friction factor | – |
| \(\nu\) | kinematic viscosity | m²/s |
Method and standards
Reynolds number by definition; Darcy friction factor 64/Re in laminar flow and Colebrook–White above (used also in transition, conservatively).
Where it is used
- Pipe and duct pressure drop.
- Heat transfer correlations.
- Choosing flowmeters.
Common mistakes
- Using kinematic viscosity as dynamic.
- Using nominal instead of inside diameter.
- Applying 64/Re in turbulent flow.
Assumptions and limits
- Full circular pipe; Newtonian fluid.
References
- Colebrook–White (1939); Moody (1944)
Questions and answers
What is Re for water at 2 m/s in DN100?
About 204 000: turbulent, with a Darcy friction factor of 0.0185 in commercial steel.
Where does laminar flow end?
Around Re 2300; above 4000 flow is turbulent; between is transition.
Darcy or Fanning?
This is the Darcy factor, four times the Fanning factor.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.