FireCADCalc

Discharge from a Tank Through an Orifice at Constant Head

Flow from an orifice or nozzle in a tank under a constant head (Torricelli with a discharge coefficient), the jet velocity and the horizontal throw of the jet.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 30 mm sharp orifice, 2.5 m head, 1 m above floorNozzle Cd 0.96, 1 m head plus 50 kPa gasShort tube Cd 0.8, 0.5 m head, at floor level

About 0.61 for a sharp-edged orifice, 0.8 for a short tube, 0.95–0.98 for a rounded nozzle.

Results

Effective head H + p_g/(ρ g)6.1088m
Jet velocity C_v √(2 g H_e)10.727m/s
Flow C_d A √(2 g H_e)11.884m³/h
Horizontal throw to the floor 2 C_v √(H_e y)3.4255m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 mm sharp orifice, 2.5 m head, 1 m above floor. The inputs, in the units selected above:

InputValue
Head above the orifice centre2.5000 m
Orifice diameter30.000 mm
Discharge coefficient0.61000 -
Velocity coefficient0.97000 -
Height of the orifice above the floor (for the throw)1.0000 m
Extra gas pressure above the liquid (gauge)0 kPa
Liquid density998.00 kg/m³

Applying the formula below gives:

ResultValue
Effective head H + p_g/(ρ g)2.5000 m
Jet velocity C_v √(2 g H_e)6.7923 m/s
Flow C_d A √(2 g H_e)10.870 m³/h
Horizontal throw to the floor 2 C_v √(H_e y)3.0674 m

Open this example in the calculator and change any input.

Formula

\(Q = C_d A \sqrt{2 g H_e}, \quad v = C_v \sqrt{2 g H_e}, \quad x = 2 C_v \sqrt{H_e\, y}\)

Variables

Symbol Meaning SI unit
\(H\) Head above the orifice centre m
\(d\) Orifice diameter m
\(C_d\) Discharge coefficient -
\(C_v\) Velocity coefficient -
\(y\) Height of the orifice above the floor (for the throw) m
\(p_g\) Extra gas pressure above the liquid (gauge) Pa
\(\rho\) Liquid density kg/m³
\(H_e\) Effective head H + p_g/(ρ g) m
\(v\) Jet velocity C_v √(2 g H_e) m/s
\(Q\) Flow C_d A √(2 g H_e) m³/s
\(x\) Horizontal throw to the floor 2 C_v √(H_e y) m

Method and standards

Torricelli's theorem.

Where it is used

  • Spill and leak estimates.
  • Fluid mechanics examinations.

Common mistakes

  • Ignoring gas pressure above the liquid.
  • Using C_v for flow.

Assumptions and limits

  • Constant head.
  • C_d = C_c C_v, so C_d should not exceed C_v (a warning is given).

References

  • Torricelli's theorem with discharge and velocity coefficients (Textbook fluid mechanics (White, Fluid Mechanics))

Questions and answers

A 30 mm sharp orifice under 2.5 m of water?

10.87 m³/h at 6.79 m/s.

Why C_d below C_v?

The jet contracts (vena contracta), so C_d = C_v × C_c.

For a draining tank?

The head falls; use the tank draining time calculator.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.