Worked example
Example: 30 mm sharp orifice, 2.5 m head, 1 m above floor. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Head above the orifice centre | 2.5000 m |
| Orifice diameter | 30.000 mm |
| Discharge coefficient | 0.61000 - |
| Velocity coefficient | 0.97000 - |
| Height of the orifice above the floor (for the throw) | 1.0000 m |
| Extra gas pressure above the liquid (gauge) | 0 kPa |
| Liquid density | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Effective head H + p_g/(ρ g) | 2.5000 m |
| Jet velocity C_v √(2 g H_e) | 6.7923 m/s |
| Flow C_d A √(2 g H_e) | 10.870 m³/h |
| Horizontal throw to the floor 2 C_v √(H_e y) | 3.0674 m |
Open this example in the calculator and change any input.
Formula
\(Q = C_d A \sqrt{2 g H_e}, \quad v = C_v \sqrt{2 g H_e}, \quad x = 2 C_v \sqrt{H_e\, y}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Head above the orifice centre | m |
| \(d\) | Orifice diameter | m |
| \(C_d\) | Discharge coefficient | - |
| \(C_v\) | Velocity coefficient | - |
| \(y\) | Height of the orifice above the floor (for the throw) | m |
| \(p_g\) | Extra gas pressure above the liquid (gauge) | Pa |
| \(\rho\) | Liquid density | kg/m³ |
| \(H_e\) | Effective head H + p_g/(ρ g) | m |
| \(v\) | Jet velocity C_v √(2 g H_e) | m/s |
| \(Q\) | Flow C_d A √(2 g H_e) | m³/s |
| \(x\) | Horizontal throw to the floor 2 C_v √(H_e y) | m |
Method and standards
Torricelli's theorem.
Where it is used
- Spill and leak estimates.
- Fluid mechanics examinations.
Common mistakes
- Ignoring gas pressure above the liquid.
- Using C_v for flow.
Assumptions and limits
- Constant head.
- C_d = C_c C_v, so C_d should not exceed C_v (a warning is given).
References
- Torricelli's theorem with discharge and velocity coefficients (Textbook fluid mechanics (White, Fluid Mechanics))
Questions and answers
A 30 mm sharp orifice under 2.5 m of water?
10.87 m³/h at 6.79 m/s.
Why C_d below C_v?
The jet contracts (vena contracta), so C_d = C_v × C_c.
For a draining tank?
The head falls; use the tank draining time calculator.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.