Worked example
Example: Air 10 000 Nm³/h at 2 bar(a), 150 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Normal flow (0 °C, 1.01325 bar) | 10,000 Nm³/h |
| Molar mass of the gas | 28.960 kg/kmol |
| Line pressure (absolute) | 2.0000 bar |
| Line temperature | 150.00 °C |
| Compressibility factor | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Actual flow at line conditions | 7,848.4 m³/h |
| Mass flow | 12,921 kg/h |
| Standard flow (15 °C, 1.01325 bar) | 10,549 m³/h |
| Density at normal conditions | 1.2921 kg/m³ |
| Density at line conditions | 1.6463 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\rho_n = \frac{p_0 M}{R T_0}, \quad \rho = \frac{p M}{Z R T}\)
\(\dot m = \dot V_n \rho_n, \quad \dot V = \dot m / \rho\)
\(\dot V_s = \dot m / \rho_s \ (15\ °C)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_n\) | normal flow (0 °C, 1.01325 bar) | Nm³/s |
| \(M\) | molar mass | kg/kmol |
| \(p\) | line pressure, absolute | Pa |
| \(T\) | line temperature | K |
| \(Z\) | compressibility factor | - |
| \(p_0\) | normal pressure 101 325 Pa | Pa |
| \(T_0\) | normal temperature 273.15 K | K |
| \(R\) | universal gas constant | J/(kmol·K) |
| \(\rho_s\) | density at 15 °C, 1.01325 bar | kg/m³ |
| \(\dot V\) | actual flow | m³/s |
| \(\dot m\) | mass flow | kg/s |
| \(\dot V_s\) | standard flow at 15 °C | m³/s |
| \(\rho_n\) | density at normal conditions | kg/m³ |
| \(\rho\) | density at line conditions | kg/m³ |
Method and standards
Mass flow is the same in any units; normal and actual volumes differ by the density ratio from the ideal gas law (with Z at line conditions).
Where it is used
- Sizing fans, ducts and gas pipes.
- Converting gas meter readings.
- Comparing data sheets that use different reference conditions.
Common mistakes
- Using gauge pressure in the gas law.
- Mixing normal (0 °C) and standard (15 °C or 60 °F) volumes.
- Forgetting water vapour in wet flue gas changes M.
Assumptions and limits
- Ideal gas at the reference conditions; Z at line conditions.
- The FPS display unit "scfm" is the US standard cubic foot per minute (60 °F, 14.696 psia), converted from the normal state; it is about 5.6 % larger than ft³/min at 0 °C for the same mass flow.
References
- Ideal gas law
Questions and answers
What is 10 000 Nm³/h of air at 2 bar(a) and 150 °C in actual m³/h?
About 7 850 m³/h; it weighs 12 900 kg/h.
What are normal and standard conditions?
Here normal is 0 °C and 1.01325 bar, standard is 15 °C and 1.01325 bar; other references exist, so check which a document uses.
Why does a fan care about actual flow?
Fans move actual volume: hot gas at low pressure occupies far more volume than its normal flow suggests.