Gas Flow: Nm³/h to Actual m³/h and kg/h

Converts a gas flow in normal cubic metres per hour to actual m³/h at line pressure and temperature, to mass flow and to standard m³/h at 15 °C, with densities.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas systemFan and blowerAir compressor and receiver

Inputs

Examples: Air 10 000 Nm³/h at 2 bar(a), 150 °CNatural gas 2 000 Nm³/h at 5 bar(a), 25 °C, Z 0.99Flue gas 60 000 Nm³/h at 1 atm, 180 °C, M 29.8

Air 28.96; natural gas about 16–19; flue gas about 29–30.

Results

Normal and standard conditions are taken as ideal gas (Z = 1); Z applies at line conditions only.

Actual flow at line conditions7,848.4m³/h
Mass flow12,921kg/h
Standard flow (15 °C, 1.01325 bar)10,549m³/h
Density at normal conditions1.2921kg/m³
Density at line conditions1.6463kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Air 10 000 Nm³/h at 2 bar(a), 150 °C. The inputs, in the units selected above:

InputValue
Normal flow (0 °C, 1.01325 bar)10,000 Nm³/h
Molar mass of the gas28.960 kg/kmol
Line pressure (absolute)2.0000 bar
Line temperature150.00 °C
Compressibility factor1.0000 -

Applying the formula below gives:

ResultValue
Actual flow at line conditions7,848.4 m³/h
Mass flow12,921 kg/h
Standard flow (15 °C, 1.01325 bar)10,549 m³/h
Density at normal conditions1.2921 kg/m³
Density at line conditions1.6463 kg/m³

Open this example in the calculator and change any input.

Formula

\(\rho_n = \frac{p_0 M}{R T_0}, \quad \rho = \frac{p M}{Z R T}\)

\(\dot m = \dot V_n \rho_n, \quad \dot V = \dot m / \rho\)

\(\dot V_s = \dot m / \rho_s \ (15\ °C)\)

Variables

Symbol Meaning SI unit
\(\dot V_n\) normal flow (0 °C, 1.01325 bar) Nm³/s
\(M\) molar mass kg/kmol
\(p\) line pressure, absolute Pa
\(T\) line temperature K
\(Z\) compressibility factor -
\(p_0\) normal pressure 101 325 Pa Pa
\(T_0\) normal temperature 273.15 K K
\(R\) universal gas constant J/(kmol·K)
\(\rho_s\) density at 15 °C, 1.01325 bar kg/m³
\(\dot V\) actual flow m³/s
\(\dot m\) mass flow kg/s
\(\dot V_s\) standard flow at 15 °C m³/s
\(\rho_n\) density at normal conditions kg/m³
\(\rho\) density at line conditions kg/m³

Method and standards

Mass flow is the same in any units; normal and actual volumes differ by the density ratio from the ideal gas law (with Z at line conditions).

Where it is used

  • Sizing fans, ducts and gas pipes.
  • Converting gas meter readings.
  • Comparing data sheets that use different reference conditions.

Common mistakes

  • Using gauge pressure in the gas law.
  • Mixing normal (0 °C) and standard (15 °C or 60 °F) volumes.
  • Forgetting water vapour in wet flue gas changes M.

Assumptions and limits

  • Ideal gas at the reference conditions; Z at line conditions.
  • The FPS display unit "scfm" is the US standard cubic foot per minute (60 °F, 14.696 psia), converted from the normal state; it is about 5.6 % larger than ft³/min at 0 °C for the same mass flow.

References

  • Ideal gas law

Questions and answers

What is 10 000 Nm³/h of air at 2 bar(a) and 150 °C in actual m³/h?

About 7 850 m³/h; it weighs 12 900 kg/h.

What are normal and standard conditions?

Here normal is 0 °C and 1.01325 bar, standard is 15 °C and 1.01325 bar; other references exist, so check which a document uses.

Why does a fan care about actual flow?

Fans move actual volume: hot gas at low pressure occupies far more volume than its normal flow suggests.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators