FireCADCalc

Free Jet: Centreline Velocity, Spread and Entrainment

Centreline and off-axis velocity of a turbulent free jet from a round nozzle or a slot, and the entrained flow at a distance (Perry's Table 6-7 and Rushton).

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Round 50 mm at 20 m/s, 2 mSlot 20 mm at 15 m/s, 1 m

Results

Air into air (Perry's Table 6-7); a water jet spreads at about 14° and entrains about 70 % as much.

Slot jet: the Rushton correlation is for round jets only, so no Rushton value is shown; the flow is per metre of slot length.

Centreline velocity4.8366m/s
Velocity at the off-axis distance4.3505m/s
Flow ratio (jet plus entrained)4.3841
Total flow at x (per metre of slot length for a slot)4,734.8m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Round 50 mm at 20 m/s, 2 m. The inputs, in the units selected above:

InputValue
Jet typeRound nozzle
Nozzle diameter or slot width50.000 mm
Jet exit velocity20.000 m/s
Distance from the nozzle2.0000 m
Distance from the centreline0.10000 m
Round-jet constant6.2 (V₀ 10–50 m/s)
Kinematic viscosity (for Rushton)15.000 cSt

Applying the formula below gives:

ResultValue
Centreline velocity3.1000 m/s
Velocity at the off-axis distance2.4624 m/s
Flow ratio (jet plus entrained)12.800
Total flow at x (per metre of slot length for a slot)1,809.6 m³/h
Centreline velocity by Rushton (round jets)3.1580 m/s

Open this example in the calculator and change any input.

Formula

\(\frac{V_c}{V_0} = K\frac{D_0}{x}, \quad \log\frac{V_c}{V_r} = 40\left(\frac{r}{x}\right)^2, \quad \frac{q}{q_0} = 0.32\frac{x}{D_0}\ \text{(round)}\)

\(\frac{V_c}{V_0} = 2.28\left(\frac{B_0}{x}\right)^{0.5}, \quad \log\frac{V_c}{V_y} = 18.4\left(\frac{y}{x}\right)^2, \quad \frac{q}{q_0} = 0.62\left(\frac{x}{B_0}\right)^{0.5}\ \text{(slot)}\)

Variables

Symbol Meaning SI unit
\(\text{type}\) Jet type -
\(D_0\) Nozzle diameter or slot width m
\(V_0\) Jet exit velocity m/s
\(x\) Distance from the nozzle m
\(r\) Distance from the centreline m
\(K\) Round-jet constant -
\(\nu\) Kinematic viscosity (for Rushton) m²/s
\(V_c\) Centreline velocity m/s
\(V_r\) Velocity at the off-axis distance m/s
\(q/q_0\) Flow ratio (jet plus entrained) -
\(q\) Total flow at x (per metre of slot length for a slot) m³/s
\(V_{c,Rushton}\) Centreline velocity by Rushton (round jets) m/s

Method and standards

Free-jet correlations.

Where it is used

  • Air throw and mixing jets.
  • Overfire air and burner jet penetration (first estimate).

Common mistakes

  • Using it close to the nozzle (potential core).
  • Ignoring walls and cross-flow.

Assumptions and limits

  • Free jets into still fluid of the same density.
  • Rushton (round jets only): V_c/V₀ = 1.41 (V₀D₀/ν)^0.135 D₀/x. The centreline velocity is capped at V₀ near the nozzle and q/q₀ at 1.
  • For a slot the flow is per metre of slot length.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 6
  • Table 6-7 (turbulent free jets) and Eq. (6-110) (Rushton, AIChE J. 26: 1038, 1980)

Questions and answers

Why does the jet slow down?

It entrains still surrounding fluid; momentum is conserved, so the growing mass flow moves more slowly.

How far does entrainment go?

At 50 diameters a round jet carries about 16 times its own flow.

Where is this used?

Air distribution, furnace and burner jets, tank mixing eductors and spray cooling.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.