Fanno Flow: Choking Length and Outlet Mach Number

Length of pipe that chokes an adiabatic gas flow from its inlet Mach number (Fanno line), and the outlet Mach number and pressure ratio for a given pipe length.

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Air, M1 0.3, DN100, 20 mSteam-like, M1 0.5, 5 m

Results

Fanno parameter at the inlet5.2993
Length to choke30.117m
Outlet Mach number0.43337
Static pressure ratio0.68569
Static temperature ratio0.98115

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Air, M1 0.3, DN100, 20 m. The inputs, in the units selected above:

InputValue
Inlet Mach number (subsonic)0.30000 -
Ratio of specific heats1.4000 -
Darcy friction factor0.018000 -
Pipe inside diameter102.30 mm
Pipe length20.000 m

Applying the formula below gives:

ResultValue
Fanno parameter at the inlet5.2993
Length to choke30.117 m
Outlet Mach number0.43337
Static pressure ratio0.68569
Static temperature ratio0.98115

Open this example in the calculator and change any input.

Formula

\(\frac{f_DL^*}{D} = \frac{1 - M^2}{\gamma M^2} + \frac{\gamma + 1}{2\gamma}\ln\frac{(\gamma + 1)M^2}{2 + (\gamma - 1)M^2}\)

\(\frac{p}{p^*} = \frac1M\sqrt{\frac{\gamma + 1}{2 + (\gamma - 1)M^2}}, \quad \frac{f_DL}{D} = \left.\frac{f_DL^*}{D}\right|_{M_1} - \left.\frac{f_DL^*}{D}\right|_{M_2}\)

Variables

Symbol Meaning SI unit
\(M_1\) Inlet Mach number (subsonic) -
\(\gamma\) Ratio of specific heats -
\(f_D\) Darcy friction factor -
\(D\) Pipe inside diameter m
\(L\) Pipe length m
\(f_DL^*/D\) Fanno parameter at the inlet -
\(L^*\) Length to choke m
\(M_2\) Outlet Mach number -
\(p_2/p_1\) Static pressure ratio -
\(T_2/T_1\) Static temperature ratio -

Method and standards

Fanno line, subsonic branch.

Where it is used

  • Relief and vent lines.
  • Compressed air and steam headers (first check).

Common mistakes

  • Using the Fanning friction factor.
  • Applying it to heated or cooled lines.

Assumptions and limits

  • Perfect gas; constant f; adiabatic; subsonic inlet.
  • When the pipe is longer than L*, the inlet Mach number falls to the value M₁′ whose choking length equals the pipe; the outlet is then sonic and the ratios are for M₁′.

References

  • Fanno-line relations for adiabatic flow of a perfect gas with friction (Shapiro, The Dynamics and Thermodynamics of Compressible Fluid Flow, 1953; Perry's Chemical Engineers' Handbook, 9th ed. (McGraw-Hill, 2019), sec. 6, adiabatic compressible flow)

Questions and answers

What is choking?

With friction, subsonic gas accelerates along the pipe; it cannot pass Mach 1 at the outlet, so a long pipe limits the flow.

Fanno or isothermal?

Fanno for short, insulated lines and vents; isothermal for long uninsulated pipelines that exchange heat with the ground.

Which friction factor?

The Darcy factor from the Moody chart at the pipe's Reynolds number (four times the Fanning value).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.