Thermal Conductivity from Electrical Conductivity (Wiedemann–Franz)

Electronic thermal conductivity of a metal from its electrical resistivity and temperature by the Wiedemann–Franz law, with the Sommerfeld Lorenz number.

Inputs

Examples: Illustrative copper at 20 CAluminium at 100 CMeasured Lorenz number for iron

Accepted: 0.01 to 10,000 µΩ·cm
Accepted: -272.15 to 2,726.8 °C
Accepted: 0 to 1E-7

Results

In metals the same free electrons carry charge and heat, so k/σ = LT with L₀ = (π²/3)(k_B/e)² = 2.44 × 10⁻⁸ W·Ω/K². It holds well for pure metals near and above room temperature (copper: 1.72 µΩ·cm at 293 K gives about 416 W/m·K, measured 398). It fails at intermediate low temperatures, and for alloys and poorer conductors the lattice (phonon) part adds noticeably to k. Enter a measured Lorenz number to override L₀.

Sommerfeld Lorenz number π²k²/3e²2.4430e-08
Electronic thermal conductivity256.79W/(m·K)
Electrical conductivity2.8169e+07S/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative copper at 20 C. The inputs, in the units selected above:

InputValue
Electrical resistivity at T1.7200 µΩ·cm
Temperature20.000 °C
Lorenz number (0 = theoretical value)0 -

Applying the formula below gives:

ResultValue
Sommerfeld Lorenz number π²k²/3e²2.4430e-08
Electronic thermal conductivity416.38 W/(m·K)
Electrical conductivity5.8140e+07 S/m

Open this example in the calculator and change any input.

Formula

\(k_e = L_0\sigma T, \quad L_0 = \frac{\pi^2}{3}\left(\frac{k_B}{e}\right)^2\)

Variables

Symbol Meaning SI unit
\(\rho\) Electrical resistivity at T Ω·m
\(T\) Temperature K
\(L\) Lorenz number (0 = theoretical value) -
\(L_0\) Sommerfeld Lorenz number π²k²/3e² -
\(k_e\) Electronic thermal conductivity W/(m·K)
\(\sigma\) Electrical conductivity S/m

Method and standards

Wiedemann–Franz.

Where it is used

  • Estimating thermal conductivity from eddy-current or resistance measurements.
  • Checking material data for consistency.

Common mistakes

  • Using room-temperature resistivity at another temperature.
  • Applying it to semiconductors or insulators.

Assumptions and limits

  • Free-electron metal; elastic scattering.

References

  • Wiedemann–Franz law with the Sommerfeld value

Questions and answers

Why is the estimate higher than measured for some metals?

Inelastic electron scattering lowers the effective Lorenz number at intermediate temperatures.

Does it work for alloys?

Approximately for the electronic part, but phonons add a significant lattice conductivity in alloys.

What do the defaults represent?

An illustrative pure copper at 20 °C, 1.72 µΩ·cm, with the theoretical Lorenz number.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Callister and Rethwisch, Materials Science and Engineering: An Introduction, 10th ed. (Wiley, 2018)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.