Worked example
Example: Illustrative carbon/epoxy 60 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fibre tensile strength | 3,500.0 MPa |
| Matrix stress at fibre failure strain | 50.000 MPa |
| Fibre modulus | 230.00 GPa |
| Matrix modulus | 3.5000 GPa |
| Fibre volume fraction | 60.000 % |
| Fibre density | 1,800.0 kg/m³ |
| Matrix density | 1,200.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Longitudinal strength | 2,120.0 MPa |
| Load carried by fibres | 98.996 % |
| Longitudinal modulus | 139.40 GPa |
| Composite density | 1,560.0 kg/m³ |
| Specific strength | 1,359.0 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\sigma_{cl}^* = \sigma_m'(1 - V_f) + \sigma_f^*V_f, \quad \frac{F_f}{F_c} = \frac{E_fV_f}{E_fV_f + E_mV_m}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\sigma_f^*\) | Fibre tensile strength | Pa |
| \(\sigma_m'\) | Matrix stress at fibre failure strain | Pa |
| \(E_f\) | Fibre modulus | Pa |
| \(E_m\) | Matrix modulus | Pa |
| \(V_f\) | Fibre volume fraction | - |
| \(\rho_f\) | Fibre density | kg/m³ |
| \(\rho_m\) | Matrix density | kg/m³ |
| \(\sigma_{cl}^*\) | Longitudinal strength | Pa |
| \(F_f/F_c\) | Load carried by fibres | - |
| \(E_{cl}\) | Longitudinal modulus | Pa |
| \(\rho_c\) | Composite density | kg/m³ |
| \(\sigma_{cl}^*/\rho_c\) | Specific strength | J/kg |
Method and standards
Composite strength.
Where it is used
- Preliminary composite design.
- Comparing fibre systems by specific strength.
Common mistakes
- Using matrix tensile strength instead of its stress at fibre failure.
- Applying longitudinal results to transverse loads.
Assumptions and limits
- Continuous aligned fibres; perfect bonding; isostrain.
References
- Rule of mixtures for aligned continuous fibres
Questions and answers
Why does the matrix contribute so little?
At the fibre failure strain the soft matrix carries a small stress, and fibres take most of the load.
Does this apply across the fibres?
No: transverse strength is controlled by the matrix and interface and is much lower.
What do the defaults represent?
An illustrative carbon/epoxy: 3.5 GPa fibres at 60 % volume, matrix at 50 MPa when the fibres break.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Callister and Rethwisch, Materials Science and Engineering: An Introduction (Wiley)