FireCADCalc

Fracture Toughness from Charpy Energy (Barsom–Rolfe)

Upper-shelf plane-strain fracture toughness of a steel from its Charpy V-notch energy and yield strength (Barsom–Rolfe), and the critical crack size.

Inputs

Examples: Illustrative 800 MPa steel, 80 J700 MPa steel, 80 JQuenched and tempered 900 MPa, 60 JTough 800 MPa, 150 J, centre crack

Accepted: 0.005 to 0.4 kJ
Accepted: 200 to 2,000 MPa
Accepted: 1 to 2,000 MPa
Accepted: 0.3 to 5

Results

Barsom–Rolfe: (K_Ic/σ_y)² = 5(CVN/σ_y − 0.05) in ksi√in, ft·lb and ksi, for upper-shelf behaviour of steels with yield 760–1,700 MPa. Outside that range or in the transition region use other correlations or direct tests; a_c = (K_Ic/Yσ)²/π.

Estimated fracture toughness (MPa·m^½)172.43
Toughness-to-yield ratio (√m)0.19159
Critical crack size30.178mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 800 MPa steel, 80 J. The inputs, in the units selected above:

InputValue
Charpy V-notch energy (upper shelf)0.080000 kJ
Yield strength800.00 MPa
Applied stress400.00 MPa
Crack geometry factor1.1200 -

Applying the formula below gives:

ResultValue
Estimated fracture toughness (MPa·m^½)193.05
Toughness-to-yield ratio (√m)0.24132
Critical crack size59.108 mm

Open this example in the calculator and change any input.

Formula

\(\left(\frac{K_{Ic}}{\sigma_y}\right)^2 = 5\left(\frac{CVN}{\sigma_y} - 0.05\right), \quad a_c = \frac1\pi\left(\frac{K_{Ic}}{Y\sigma}\right)^2\)

Variables

Symbol Meaning SI unit
\(CVN\) Charpy V-notch energy (upper shelf) J
\(\sigma_y\) Yield strength Pa
\(\sigma\) Applied stress Pa
\(Y\) Crack geometry factor -
\(K_{Ic}\) Estimated fracture toughness (MPa·m^½) -
\(K_{Ic}/\sigma_y\) Toughness-to-yield ratio (√m) -
\(a_c\) Critical crack size m

Method and standards

Barsom–Rolfe.

Where it is used

  • Fracture screening of steel structures and vessels.
  • Choosing steel grades for toughness.

Common mistakes

  • Using it in the transition range.
  • Mixing SI with the correlation's US units.

Assumptions and limits

  • Upper-shelf behaviour; medium- and high-strength steels.

References

  • Barsom–Rolfe upper-shelf correlation

Questions and answers

Why estimate K_Ic from Charpy?

Charpy tests are cheap and common; valid K_Ic tests need thick specimens and are costly.

Is the correlation conservative?

Reasonably on the upper shelf; in the ductile-brittle transition it can be badly wrong.

What do the defaults represent?

An illustrative 800 MPa yield steel with 80 J upper-shelf Charpy energy, loaded to 400 MPa with an edge crack (Y = 1.12).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Barsom and Rolfe, Fracture and Fatigue Control in Structures, 3rd ed. (ASTM, 1999)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.