UV Disinfection: Dose, Log Inactivation and Exposure Time

UV dose from average intensity and exposure time, the log inactivation for an organism's dose per log, and the exposure needed for a target log reduction.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 100 W/m2 for 4 sLow UVT effluent

Does not change the dose: the average intensity entered must already allow for the water's transmittance.

Results

Low UV transmittance: the average intensity falls steeply; check the reactor rating at this UVT.

Log-linear inactivation assumed; validated reactors are rated by a biodosimetric (RED) dose, not by average intensity × time.

UV dose (mJ/cm²)24.000
Log inactivation achieved1.2000
Exposure time for the target15.000s
Dose for the target (mJ/cm²)60.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 W/m2 for 4 s. The inputs, in the units selected above:

InputValue
Average UV intensity100.00 W/m²
Exposure time4.0000 s
Dose per log inactivation (mJ/cm²)10.000 -
Target log inactivation4.0000 -
UV transmittance (1 cm), for the low-UVT check only65.000 %

Applying the formula below gives:

ResultValue
UV dose (mJ/cm²)40.000
Log inactivation achieved4.0000
Exposure time for the target4.0000 s
Dose for the target (mJ/cm²)40.000

Open this example in the calculator and change any input.

Formula

\(D = I\,t, \quad \log_{10}\frac{N_0}{N} = \frac{D}{D_{10}}, \quad t_{req} = \frac{\log\cdot D_{10}}{I}\)

Variables

Symbol Meaning SI unit
\(I\) Average UV intensity W/m²
\(t\) Exposure time s
\(D_{10}\) Dose per log inactivation (mJ/cm²) -
\(\log_{10}\) Target log inactivation -
\(UVT\) UV transmittance (1 cm), for the low-UVT check only -
\(D\) UV dose (mJ/cm²) -
\(t_{req}\) Exposure time for the target s
\(D_{req}\) Dose for the target (mJ/cm²) -

Method and standards

Dose definitions.

Where it is used

  • Drinking water, effluent and process water UV.
  • Food and beverage water.

Common mistakes

  • Ignoring transmittance and lamp ageing.
  • Using one organism's D₁₀ for another.

Assumptions and limits

  • UVT does not enter the dose: it only triggers a warning below 55 %. The average intensity I must be the value in the water at its transmittance (from the reactor maker or a fluence-rate calculation).

  • Log-linear kinetics; uniform intensity.

References

  • UV dose D = I·t; log-linear inactivation with dose per log (US EPA, Ultraviolet Disinfection Guidance Manual, EPA 815-R-06-007)

Questions and answers

What units is UV dose in?

mJ/cm², numerically the same as mW·s/cm²; 1 mJ/cm² = 10 J/m².

What dose is typical?

About 40 mJ/cm² for drinking water; effluent reuse often 80–100 mJ/cm² or more.

What do the defaults give?

100 W/m² for 4 s: 40 mJ/cm², 4 logs at 10 mJ/cm² per log.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.