Worked example
Example: 100 W/m2 for 4 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Average UV intensity | 100.00 W/m² |
| Exposure time | 4.0000 s |
| Dose per log inactivation (mJ/cm²) | 10.000 - |
| Target log inactivation | 4.0000 - |
| UV transmittance (1 cm), for the low-UVT check only | 65.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| UV dose (mJ/cm²) | 40.000 |
| Log inactivation achieved | 4.0000 |
| Exposure time for the target | 4.0000 s |
| Dose for the target (mJ/cm²) | 40.000 |
Open this example in the calculator and change any input.
Formula
\(D = I\,t, \quad \log_{10}\frac{N_0}{N} = \frac{D}{D_{10}}, \quad t_{req} = \frac{\log\cdot D_{10}}{I}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(I\) | Average UV intensity | W/m² |
| \(t\) | Exposure time | s |
| \(D_{10}\) | Dose per log inactivation (mJ/cm²) | - |
| \(\log_{10}\) | Target log inactivation | - |
| \(UVT\) | UV transmittance (1 cm), for the low-UVT check only | - |
| \(D\) | UV dose (mJ/cm²) | - |
| \(t_{req}\) | Exposure time for the target | s |
| \(D_{req}\) | Dose for the target (mJ/cm²) | - |
Method and standards
Dose definitions.
Where it is used
- Drinking water, effluent and process water UV.
- Food and beverage water.
Common mistakes
- Ignoring transmittance and lamp ageing.
- Using one organism's D₁₀ for another.
Assumptions and limits
UVT does not enter the dose: it only triggers a warning below 55 %. The average intensity I must be the value in the water at its transmittance (from the reactor maker or a fluence-rate calculation).
Log-linear kinetics; uniform intensity.
References
- UV dose D = I·t; log-linear inactivation with dose per log (US EPA, Ultraviolet Disinfection Guidance Manual, EPA 815-R-06-007)
Questions and answers
What units is UV dose in?
mJ/cm², numerically the same as mW·s/cm²; 1 mJ/cm² = 10 J/m².
What dose is typical?
About 40 mJ/cm² for drinking water; effluent reuse often 80–100 mJ/cm² or more.
What do the defaults give?
100 W/m² for 4 s: 40 mJ/cm², 4 logs at 10 mJ/cm² per log.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.