Secondary Clarifier: Surface Overflow and Solids Loading

Clarifier area needed by surface overflow rate and by solids loading rate for an activated sludge plant, with the governing area, diameter and the actual rates.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 000 m3/d, MLSS 3500High MLSS 5000, R 1

Results

Typical limits for activated sludge: overflow 16–28 m³/(m²·d) average and 40–64 at peak; solids loading 4–6 kg/(m²·h) average and up to 8–10 at peak (Metcalf & Eddy). A state-point analysis with settling data is better than fixed limits.

Area by overflow rate208.33m²
Area by solids loading390.62m²
Governing area390.62m²
Diameter of each clarifier15.770m
Overflow rate at average flow0.53333m/h
Solids loading at average flow5.3333kg/(m²·h)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 000 m3/d, MLSS 3500. The inputs, in the units selected above:

InputValue
Average influent flow10,000 m³/d
Peak flow factor2.5000 -
Return sludge ratio0.50000 -
MLSS3,500.0 mg/L
Maximum surface overflow rate at peak1.6667 m/h
Maximum solids loading rate at peak9.0000 kg/(m²·h)
Number of clarifiers2.0000 -

Applying the formula below gives:

ResultValue
Area by overflow rate625.00 m²
Area by solids loading486.11 m²
Governing area625.00 m²
Diameter of each clarifier19.947 m
Overflow rate at average flow0.66667 m/h
Solids loading at average flow3.5000 kg/(m²·h)

Open this example in the calculator and change any input.

Formula

\(A_{SOR} = \frac{Q_p}{SOR_{max}}, \quad A_{SLR} = \frac{(Q_p + RQ)X}{SLR_{max}}, \quad A = \max(A_{SOR}, A_{SLR})\)

Variables

Symbol Meaning SI unit
\(Q\) Average influent flow m³/s
\(PF\) Peak flow factor -
\(R\) Return sludge ratio -
\(X\) MLSS kg/m³
\(SOR_{max}\) Maximum surface overflow rate at peak m/s
\(SLR_{max}\) Maximum solids loading rate at peak kg/(m²·s)
\(n\) Number of clarifiers -
\(A_{SOR}\) Area by overflow rate m²
\(A_{SLR}\) Area by solids loading m²
\(A\) Governing area m²
\(D\) Diameter of each clarifier m
\(SOR_{avg}\) Overflow rate at average flow m/s
\(SLR_{avg}\) Solids loading at average flow kg/(m²·s)

Method and standards

Overflow and solids loading definitions.

Where it is used

  • Activated sludge plant design.
  • Checking clarifiers before raising MLSS.

Common mistakes

  • Using average flow only.
  • Ignoring return sludge in the solids loading.

Assumptions and limits

  • Circular clarifiers of equal size; the number of clarifiers is a whole number (a fractional entry is rounded, with a note).

References

  • Metcalf & Eddy
  • Wastewater Engineering: Treatment and Resource Recovery
  • 5th ed. (McGraw-Hill, 2014)
  • ch. 8 (secondary clarifier overflow and solids loading rates)

Questions and answers

Which limit usually governs?

Solids loading at peak flow for plants with high MLSS; overflow rate for low MLSS or high peak factors.

Why include return flow in solids loading?

The clarifier carries influent plus return sludge downward; both bring solids to the sludge blanket.

What do the defaults give?

10,000 m³/d, peak 2.5, MLSS 3,500 mg/L: overflow rate governs: about 625 m² in total, two clarifiers of about 20 m.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.