FireCADCalc

Effluent Neutralisation: Acid or Alkali Dose

Dose and daily use of caustic, lime, soda ash, sulphuric or hydrochloric acid to neutralise an effluent, from its titrated acidity or alkalinity as CaCO₃.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textileWater treatment plant

Inputs

Examples: Acidic effluent 20 m³/h, 500 mg/L acidity, 48 % caustic, pH 3DM regeneration waste 15 m³/h, 1 200 mg/L, 90 % limeAlkaline effluent 10 m³/h, 800 mg/L alkalinity, 98 % sulphuric acid, pH 11.5

For example 48 % caustic lye, 98 % sulphuric acid, 33 % hydrochloric acid, 90 % hydrated lime.

Results

Real effluents are buffered: dose from a titration of the actual effluent; the pH-only figure is a lower bound for strong acids or bases.

Dose of the chemical as supplied832.55mg/L
Chemical as supplied16.651kg/h
Chemical per day399.63kg
Acidity or alkalinity from pH alone (strong acid or base, as CaCO₃)50.043mg/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Acidic effluent 20 m³/h, 500 mg/L acidity, 48 % caustic, pH 3. The inputs, in the units selected above:

InputValue
Effluent flow20.000 m³/h
Neutralising chemicalCaustic soda NaOH (for acidic effluent)
Strength of the chemical as supplied48.000 %
Acidity or alkalinity to remove, as CaCO₃ (from a titration to the target pH)500.00 mg/L
Effluent pH, for a strong-acid or strong-base check (0 = none, so a pH of exactly 0 cannot be checked)3.0000 -

Applying the formula below gives:

ResultValue
Dose of the chemical as supplied832.55 mg/L
Chemical as supplied16.651 kg/h
Chemical per day399.63 kg
Acidity or alkalinity from pH alone (strong acid or base, as CaCO₃)50.043 mg/L

Open this example in the calculator and change any input.

Formula

\(D = A_c \frac{E_r}{E_{CaCO_3}} \cdot \frac{1}{s}\)

\(\dot m_r = D\, Q, \quad m_d = \dot m_r \cdot 86\,400\ \text{s}\)

\(A_{pH} = 10^{-pH} \ \text{(or } K_w / 10^{-pH}\text{) eq/L} \times E_{CaCO_3}\)

Variables

Symbol Meaning SI unit
\(Q\) effluent flow m³/s
\(\text{reagent}\) neutralising chemical -
\(s\) strength as supplied -
\(A_c\) acidity or alkalinity as CaCO₃ kg/m³
\(pH\) Effluent pH, for a strong-acid or strong-base check (0 = none, so a pH of exactly 0 cannot be checked) -
\(E_r\) equivalent mass of the reagent kg/kmol
\(E_{CaCO_3}\) equivalent mass of CaCO₃ (50.04) kg/kmol
\(K_w\) ionic product of water at 25 °C (mol/L)²
\(D\) dose as supplied kg/m³
\(\dot m_r\) chemical rate kg/s
\(m_d\) chemical per day kg
\(A_{pH}\) acidity from pH alone kg/m³

Method and standards

Acidity measured as CaCO₃ converts to any reagent by the ratio of equivalent masses (NaOH 40.0, Ca(OH)₂ 37.0, Na₂CO₃ 53.0, H₂SO₄ 49.0, HCl 36.5, CaCO₃ 50.0), then to product by its strength. The pH-only figure applies to unbuffered strong acids or bases.

Where it is used

  • Sizing neutralisation dosing pumps and tanks.
  • Estimating chemical costs for an ETP.
  • Neutralising DM plant regeneration waste.

Common mistakes

  • Dosing from pH alone on buffered effluent.
  • Forgetting the product strength.
  • Overshooting with strong reagents in small tanks.

Assumptions and limits

  • Dose from titration to the target pH; reaction complete.

References

  • Equivalent-weight stoichiometry (acidity as CaCO₃)

Questions and answers

How much 48 % caustic neutralises 20 m³/h with 500 mg/L acidity?

About 830 mg/L of product: 16.7 kg/h or 400 kg/day.

Why titrate instead of using pH?

Real effluents are buffered: their acidity is far more than the free H⁺ that pH shows. pH 3 alone suggests only 50 mg/L as CaCO₃.

Which chemical is cheapest?

Lime is usually cheapest for acids but makes sludge; caustic is cleaner; compare by cost per equivalent.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.