FireCADCalc

BOD₅ from Dilution Bottle Readings (Seeded or Unseeded)

Five-day BOD of a sample from initial and final dissolved oxygen of the diluted sample and seed blank, the dilution fraction and the seed correction.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Seeded effluent at 2 %Unseeded river water at 50 %

Results

BOD₅ (mg/L)6.8000
Oxygen depletion in the sample bottle (mg/L)3.4000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Seeded effluent at 2 %. The inputs, in the units selected above:

InputValue
Initial DO of the diluted sample (mg/L)8.6000 -
DO after 5 days (mg/L)4.1000 -
Sample share of the bottle (volume fraction)2.0000 %
Initial DO of the seed blank (mg/L)8.7000 -
Final DO of the seed blank (mg/L)7.9000 -
Seed in sample bottle / seed in blank (0 if unseeded)20.000 %

Applying the formula below gives:

ResultValue
BOD₅ (mg/L)217.00
Oxygen depletion in the sample bottle (mg/L)4.5000

Open this example in the calculator and change any input.

Formula

\(BOD_5 = \frac{(D_1 - D_2) - (B_1 - B_2)f}{P}\)

Variables

Symbol Meaning SI unit
\(D_1\) Initial DO of the diluted sample (mg/L) -
\(D_2\) DO after 5 days (mg/L) -
\(P\) Sample share of the bottle (volume fraction) -
\(B_1\) Initial DO of the seed blank (mg/L) -
\(B_2\) Final DO of the seed blank (mg/L) -
\(f\) Seed in sample bottle / seed in blank (0 if unseeded) -
\(BOD_5\) BOD₅ (mg/L) -
\(\Delta DO\) Oxygen depletion in the sample bottle (mg/L) -

Method and standards

Standard Methods.

Where it is used

  • ETP laboratories.
  • Effluent compliance.

Common mistakes

  • P as a percentage.
  • Ignoring seed oxygen use.

Assumptions and limits

  • 20 °C incubation, 5 days.
  • Only the sample bottle's depletion and residual DO are checked; the seed-control and dilution-water blank acceptance criteria of Standard Methods 5210 B are not.
  • A negative BOD₅ (seed correction larger than the depletion) is flagged as invalid.

References

  • BOD₅ = [(D₁ − D₂) − (B₁ − B₂)f]/P (Standard Methods 5210 B)

Questions and answers

DO 8.6 → 4.1 at 2 % sample, seed correction 0.8 × 0.2?

BOD₅ about 217 mg/L.

Unseeded?

Set f to zero: BOD₅ = (D₁ − D₂)/P.

Valid range?

Depletion at least 2 mg/L with at least 1 mg/L left.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.