Worked example
Example: Seeded effluent at 2 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial DO of the diluted sample (mg/L) | 8.6000 - |
| DO after 5 days (mg/L) | 4.1000 - |
| Sample share of the bottle (volume fraction) | 2.0000 % |
| Initial DO of the seed blank (mg/L) | 8.7000 - |
| Final DO of the seed blank (mg/L) | 7.9000 - |
| Seed in sample bottle / seed in blank (0 if unseeded) | 20.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| BOD₅ (mg/L) | 217.00 |
| Oxygen depletion in the sample bottle (mg/L) | 4.5000 |
Open this example in the calculator and change any input.
Formula
\(BOD_5 = \frac{(D_1 - D_2) - (B_1 - B_2)f}{P}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_1\) | Initial DO of the diluted sample (mg/L) | - |
| \(D_2\) | DO after 5 days (mg/L) | - |
| \(P\) | Sample share of the bottle (volume fraction) | - |
| \(B_1\) | Initial DO of the seed blank (mg/L) | - |
| \(B_2\) | Final DO of the seed blank (mg/L) | - |
| \(f\) | Seed in sample bottle / seed in blank (0 if unseeded) | - |
| \(BOD_5\) | BOD₅ (mg/L) | - |
| \(\Delta DO\) | Oxygen depletion in the sample bottle (mg/L) | - |
Method and standards
Standard Methods.
Where it is used
- ETP laboratories.
- Effluent compliance.
Common mistakes
- P as a percentage.
- Ignoring seed oxygen use.
Assumptions and limits
- 20 °C incubation, 5 days.
- Only the sample bottle's depletion and residual DO are checked; the seed-control and dilution-water blank acceptance criteria of Standard Methods 5210 B are not.
- A negative BOD₅ (seed correction larger than the depletion) is flagged as invalid.
References
- BOD₅ = [(D₁ − D₂) − (B₁ − B₂)f]/P (Standard Methods 5210 B)
Questions and answers
DO 8.6 → 4.1 at 2 % sample, seed correction 0.8 × 0.2?
BOD₅ about 217 mg/L.
Unseeded?
Set f to zero: BOD₅ = (D₁ − D₂)/P.
Valid range?
Depletion at least 2 mg/L with at least 1 mg/L left.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.