Worked example
Example: BOD5 200, k 0.23/d, 10 days. The inputs, in the units selected above:
| Input | Value |
|---|---|
| BOD₅ (mg/L) | 200.00 - |
| Rate constant (base e) | 0.23000 1/d |
| Time of interest | 10.000 d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ultimate BOD (mg/L) | 292.67 |
| BOD exerted at t (mg/L) | 263.33 |
| BOD₅ share of ultimate | 68.336 % |
Open this example in the calculator and change any input.
Formula
\(BOD_t = L_0\left(1 - e^{-kt}\right), \quad L_0 = \frac{BOD_5}{1 - e^{-5k}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(BOD_5\) | BOD₅ (mg/L) | - |
| \(k\) | Rate constant (base e) | 1/s |
| \(t\) | Time of interest | s |
| \(L_0\) | Ultimate BOD (mg/L) | - |
| \(BOD_t\) | BOD exerted at t (mg/L) | - |
| \(BOD_5/L_0\) | BOD₅ share of ultimate | - |
Method and standards
First order.
Where it is used
- Effluent oxygen demand.
- Examinations.
Common mistakes
- Base-10 k used as base e.
- Days vs seconds.
Assumptions and limits
- Carbonaceous BOD only.
- BOD₅ is the 5-day test at 20 °C. Do not enter the Indian 3-day, 27 °C BOD (IS 3025) as BOD₅: its incubation time and rate constant differ.
References
- BOD_t = L₀(1 − e^(−kt)) (first-order BOD kinetics, Metcalf & Eddy)
Questions and answers
BOD₅ 200 with k 0.23/d?
Ultimate about 293 mg/L; 263 after 10 days.
Base 10 constants?
Multiply a base-10 k by 2.303.
Nitrogenous demand?
Appears after a week or so and is not in this first-order model.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.