FireCADCalc

Aeration Tank HRT, F/M Ratio and Sludge Age (SRT)

Hydraulic retention time, food-to-microorganism (F/M) ratio and sludge age of an activated sludge aeration tank from the flow, BOD, volume, MLSS and sludge wasting.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 1 000 m³/d, BOD 250, 300 m³, MLSS 3 000, wasting 10 m³/d at 8 000Extended aeration: 200 m³/d, BOD 300, 250 m³, 4 000, 2 m³/d at 10 0005 000 m³/d, BOD 180, 1 200 m³, 2 500, 60 m³/d at 7 000, no effluent solids

Sludge wasting

Results

Steady-state mass balance on the aeration tank (Metcalf & Eddy definitions); clarifier inventory is not included in the sludge age.

Hydraulic retention time V / Q5.7600h
Food to microorganism ratio Q S₀ / (V X)0.300001/d
Sludge age V X / (Q_w X_w + (Q − Q_w) X_e)7.1429d
BOD loading on the tank volume0.75000kg/(m³·d)
Solids under aeration3,000.0kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 000 m³/d, BOD 250, 300 m³, MLSS 3 000, wasting 10 m³/d at 8 000. The inputs, in the units selected above:

InputValue
Influent flow1,000.0 m³/d
Influent BOD250.00 mg/L
Aeration tank volume300.00 m³
MLSS (or MLVSS) in the tank3,000.0 mg/L
Waste sludge flow10.000 m³/d
Solids in the waste sludge8,000.0 mg/L
Solids in the treated effluent20.000 mg/L

Applying the formula below gives:

ResultValue
Hydraulic retention time V / Q7.2000 h
Food to microorganism ratio Q S₀ / (V X)0.27778 1/d
Sludge age V X / (Q_w X_w + (Q − Q_w) X_e)9.0180 d
BOD loading on the tank volume0.83333 kg/(m³·d)
Solids under aeration900.00 kg

Open this example in the calculator and change any input.

Formula

\(\theta = \frac{V}{Q}, \quad F/M = \frac{Q\, S_0}{V\, X}\)

\(\theta_c = \frac{V X}{Q_w X_w + (Q - Q_w) X_e}\)

Variables

Symbol Meaning SI unit
\(Q\) Influent flow m³/s
\(S_0\) Influent BOD kg/m³
\(V\) Aeration tank volume m³
\(X\) MLSS (or MLVSS) in the tank kg/m³
\(Q_w\) Waste sludge flow m³/s
\(X_w\) Solids in the waste sludge kg/m³
\(X_e\) Solids in the treated effluent kg/m³
\(\theta\) Hydraulic retention time V / Q s
\(F/M\) Food to microorganism ratio Q S₀ / (V X) 1/s
\(\theta_c\) Sludge age V X / (Q_w X_w + (Q − Q_w) X_e) s
\(OLR\) BOD loading on the tank volume kg/(m³·s)
\(M_X\) Solids under aeration kg

Method and standards

Steady-state mass balances on the aeration tank.

Where it is used

  • ETP and STP operation.
  • Troubleshooting bulking.
  • Design checks.

Common mistakes

  • MLSS and MLVSS mixed.
  • Leaving out effluent solids.

Assumptions and limits

  • Steady state; clarifier inventory ignored.
  • Waste solids below the MLSS, or effluent solids above it, are flagged as implausible.

References

  • Metcalf & Eddy
  • Wastewater Engineering (activated sludge definitions)

Questions and answers

What are HRT, F/M and sludge age for 1000 m³/d, BOD 250, a 300 m³ tank at 3000 mg/L MLSS?

HRT 7.2 h, F/M 0.28 per day, and with 10 m³/d wasted at 8000 mg/L (effluent 20 mg/L) a sludge age of 9.0 days.

What F/M is usual?

Your design basis decides; conventional plants run higher F/M than extended aeration.

Why include effluent solids?

They leave the system too, shortening the sludge age.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.