Worked example
Example: 1 000 m³/d, BOD 250, 300 m³, MLSS 3 000, wasting 10 m³/d at 8 000. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Influent flow | 1,000.0 m³/d |
| Influent BOD | 250.00 mg/L |
| Aeration tank volume | 300.00 m³ |
| MLSS (or MLVSS) in the tank | 3,000.0 mg/L |
| Waste sludge flow | 10.000 m³/d |
| Solids in the waste sludge | 8,000.0 mg/L |
| Solids in the treated effluent | 20.000 mg/L |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic retention time V / Q | 7.2000 h |
| Food to microorganism ratio Q S₀ / (V X) | 0.27778 1/d |
| Sludge age V X / (Q_w X_w + (Q − Q_w) X_e) | 9.0180 d |
| BOD loading on the tank volume | 0.83333 kg/(m³·d) |
| Solids under aeration | 900.00 kg |
Open this example in the calculator and change any input.
Formula
\(\theta = \frac{V}{Q}, \quad F/M = \frac{Q\, S_0}{V\, X}\)
\(\theta_c = \frac{V X}{Q_w X_w + (Q - Q_w) X_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Influent flow | m³/s |
| \(S_0\) | Influent BOD | kg/m³ |
| \(V\) | Aeration tank volume | m³ |
| \(X\) | MLSS (or MLVSS) in the tank | kg/m³ |
| \(Q_w\) | Waste sludge flow | m³/s |
| \(X_w\) | Solids in the waste sludge | kg/m³ |
| \(X_e\) | Solids in the treated effluent | kg/m³ |
| \(\theta\) | Hydraulic retention time V / Q | s |
| \(F/M\) | Food to microorganism ratio Q S₀ / (V X) | 1/s |
| \(\theta_c\) | Sludge age V X / (Q_w X_w + (Q − Q_w) X_e) | s |
| \(OLR\) | BOD loading on the tank volume | kg/(m³·s) |
| \(M_X\) | Solids under aeration | kg |
Method and standards
Steady-state mass balances on the aeration tank.
Where it is used
- ETP and STP operation.
- Troubleshooting bulking.
- Design checks.
Common mistakes
- MLSS and MLVSS mixed.
- Leaving out effluent solids.
Assumptions and limits
- Steady state; clarifier inventory ignored.
- Waste solids below the MLSS, or effluent solids above it, are flagged as implausible.
References
- Metcalf & Eddy
- Wastewater Engineering (activated sludge definitions)
Questions and answers
What are HRT, F/M and sludge age for 1000 m³/d, BOD 250, a 300 m³ tank at 3000 mg/L MLSS?
HRT 7.2 h, F/M 0.28 per day, and with 10 m³/d wasted at 8000 mg/L (effluent 20 mg/L) a sludge age of 9.0 days.
What F/M is usual?
Your design basis decides; conventional plants run higher F/M than extended aeration.
Why include effluent solids?
They leave the system too, shortening the sludge age.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.