FireCADCalc

Hindered Settling Velocity (Richardson–Zaki)

Settling velocity of a suspension from the Stokes velocity and voidage, u = u_t εⁿ, with the Richardson–Zaki exponent from the particle Reynolds number.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 100 µm sand, 20 % solids30 µm lime, 10 %1 mm sand, terminal velocity 0.1 m/s entered

Leave 0 to use Stokes' law. Above the Stokes range enter u_t from the particle terminal velocity calculator.

Results

Re above the Stokes range: the single-particle velocity is overstated; use a drag correlation for u_t.

Single-particle (Stokes) velocity0.009000m/s
Particle Reynolds number0.89823
Richardson–Zaki exponent4.4142
Hindered settling velocity0.003361m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 µm sand, 20 % solids. The inputs, in the units selected above:

InputValue
Particle diameter0.10000 mm
Particle density2,650.0 kg/m³
Fluid density998.00 kg/m³
Fluid viscosity1.0000 cP
Solids volume fraction20.000 %
Single-particle terminal velocity, if known (0 = Stokes)0 m/s

Applying the formula below gives:

ResultValue
Single-particle (Stokes) velocity0.009000 m/s
Particle Reynolds number0.89823
Richardson–Zaki exponent4.4142
Hindered settling velocity0.003361 m/s

Open this example in the calculator and change any input.

Formula

\(u_t = \frac{(\rho_p - \rho_f)g d_p^2}{18\mu}\ \text{(or } u_{t,in}\text{ if entered)}, \quad Re_t = \frac{\rho_f u_t d_p}{\mu}, \quad u = u_t(1 - \phi)^n\)

Variables

Symbol Meaning SI unit
\(d_p\) Particle diameter m
\(\rho_p\) Particle density kg/m³
\(\rho_f\) Fluid density kg/m³
\(\mu\) Fluid viscosity Pa·s
\(\phi\) Solids volume fraction -
\(u_t\) Single-particle (Stokes) velocity m/s
\(Re_t\) Particle Reynolds number -
\(n\) Richardson–Zaki exponent -
\(u\) Hindered settling velocity m/s
\(u_{t,in}\) Single-particle terminal velocity, if known (0 = Stokes) m/s
\(g\) Standard gravity, 9.806 65 m/s²

Method and standards

Stokes' law with the Richardson–Zaki correction.

Where it is used

  • Thickener and classifier design.
  • Fluidised-bed expansion.

Common mistakes

  • Using Stokes' law outside Re < 0.3.
  • Using volume fraction by mass.

Assumptions and limits

  • Uniform spheres.
  • Stokes' law is used only while Re_t stays below 1; beyond that the calculation stops unless you enter the single-particle terminal velocity from a drag correlation (for example the particle terminal velocity calculator). The exponent n is then taken at the Re of that velocity.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 17: Richardson and Zaki
  • U/Uᵢ = εⁿ [Trans. Inst. Chem. Eng. 32: 35 (1954)]
  • Richardson–Zaki exponent: 4.65 (Re < 0.2)
  • 4.4 Re^−0.03 (0.2–1)
  • 4.4 Re^−0.1 (1–500)
  • 2.4 (> 500)

Questions and answers

Why does a slurry settle slower than one particle?

Displaced fluid flows up between the particles and the suspension's effective density and viscosity rise.

What exponent applies?

4.65 in the Stokes range, falling to 2.4 at high Reynolds numbers.

Does it apply to flocculated slurries?

Poorly; use batch settling tests.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.