Reflux Condenser (Dephlegmator): Tube Flooding Check

Checks whether the tubes of a vertical reflux condenser with vapour rising and condensate falling will flood, from the flooding criterion of the two velocities.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative: 4 kg/s vapour up, 3 kg/s condensate down, 300 tubes of 40 mmOverloaded vent condenser, 40 tubes of 25 mm

Accepted: 3.6 to 360,000 kg/h
Accepted: 3.6 to 360,000 kg/h
Accepted: 1 to 10,000
Accepted: 10 to 100 mm
Accepted: 0.05 to 100 kg/m³
Accepted: 300 to 2,000 kg/m³

Results

Flooding criterion for counter-current vapour and condensate in vertical tubes; velocities are superficial (each phase alone in the full tube area), at the tube inlet where both flows are largest.

The tubes will flood: add tubes, use larger tubes or reduce the vapour load.

Vapour velocity (vapour alone)22.635m/s
Liquid velocity (liquid alone)0.028294m/s
Flooding group of the flows6.4321
Flooding limit2.3113
Flows as a share of the flooding limit278.29%
Fewest tubes that avoid flooding310.00

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 4 kg/s vapour up, 3 kg/s condensate down, 300 tubes of 40 mm. The inputs, in the units selected above:

InputValue
Vapour entering the tubes14,400 kg/h
Condensate returning down the tubes10,800 kg/h
Number of tubes300.00 -
Tube inside diameter40.000 mm
Vapour density3.0000 kg/m³
Liquid density780.00 kg/m³

Applying the formula below gives:

ResultValue
Vapour velocity (vapour alone)3.5368 m/s
Liquid velocity (liquid alone)0.010202 m/s
Flooding group of the flows3.0088
Flooding limit2.5070
Flows as a share of the flooding limit120.02 %
Fewest tubes that avoid flooding433.00

Open this example in the calculator and change any input.

Formula

\(u_v^{1/2}\rho_v^{1/4} + u_L^{1/2}\rho_L^{1/4} < 0.6\left[g\,d_i(\rho_L - \rho_v)\right]^{1/4}\)

\(u_v = \frac{\dot m_v}{n_t\,\pi d_i^2/4\;\rho_v}, \quad u_L = \frac{\dot m_l}{n_t\,\pi d_i^2/4\;\rho_L}\)

Variables

Symbol Meaning SI unit
\(\dot m_v\) Vapour entering the tubes kg/s
\(\dot m_l\) Condensate returning down the tubes kg/s
\(n_t\) Number of tubes -
\(d_i\) Tube inside diameter m
\(\rho_v\) Vapour density kg/m³
\(\rho_L\) Liquid density kg/m³
\(u_v\) Vapour velocity (vapour alone) m/s
\(u_L\) Liquid velocity (liquid alone) m/s
\(u_v^{1/2}\rho_v^{1/4} + u_L^{1/2}\rho_L^{1/4}\) Flooding group of the flows -
\(0.6[g d_i(\rho_L - \rho_v)]^{1/4}\) Flooding limit -
\(\text{ratio}\) Flows as a share of the flooding limit -
\(n_{t,min}\) Fewest tubes that avoid flooding -

Method and standards

Empirical flooding limit for counter-current two-phase flow in vertical tubes.

Where it is used

  • Reflux (knock-back) condensers on columns.
  • Vent condensers with returning condensate.

Common mistakes

  • Using the distillate rate as the vapour rate.
  • Checking at the top of the tubes, where flows are smallest.

Assumptions and limits

  • Vertical tubes, vapour up and condensate down; rough guide only.

References

  • Counter-current flooding criterion [u_v^½ ρ_v^¼ + u_L^½ ρ_L^¼] < 0.6[g d_i(ρ_L − ρ_v)]^¼

Questions and answers

Where is flooding most likely?

At the bottom of the tubes, where all the vapour enters and all the condensate leaves.

How do I find the flows?

Vapour = (R + 1) × distillate and condensate = R × distillate for a total reflux condenser with reflux ratio R.

What do the defaults represent?

An illustrative column top: 4 kg/s of vapour at 3 kg/m³ rising and 3 kg/s of condensate at 780 kg/m³ falling through 300 tubes of 40 mm bore.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 12.10.3, eq. 12.55 and Example 12.6

Related calculators