Example: Illustrative: 4 kg/s vapour up, 3 kg/s condensate down, 300 tubes of 40 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour entering the tubes | 14,400 kg/h |
| Condensate returning down the tubes | 10,800 kg/h |
| Number of tubes | 300.00 - |
| Tube inside diameter | 40.000 mm |
| Vapour density | 3.0000 kg/m³ |
| Liquid density | 780.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour velocity (vapour alone) | 3.5368 m/s |
| Liquid velocity (liquid alone) | 0.010202 m/s |
| Flooding group of the flows | 3.0088 |
| Flooding limit | 2.5070 |
| Flows as a share of the flooding limit | 120.02 % |
| Fewest tubes that avoid flooding | 433.00 |
Open this example in the calculator and change any input.
Formula
\(u_v^{1/2}\rho_v^{1/4} + u_L^{1/2}\rho_L^{1/4} < 0.6\left[g\,d_i(\rho_L - \rho_v)\right]^{1/4}\)
\(u_v = \frac{\dot m_v}{n_t\,\pi d_i^2/4\;\rho_v}, \quad u_L = \frac{\dot m_l}{n_t\,\pi d_i^2/4\;\rho_L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_v\) | Vapour entering the tubes | kg/s |
| \(\dot m_l\) | Condensate returning down the tubes | kg/s |
| \(n_t\) | Number of tubes | - |
| \(d_i\) | Tube inside diameter | m |
| \(\rho_v\) | Vapour density | kg/m³ |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(u_v\) | Vapour velocity (vapour alone) | m/s |
| \(u_L\) | Liquid velocity (liquid alone) | m/s |
| \(u_v^{1/2}\rho_v^{1/4} + u_L^{1/2}\rho_L^{1/4}\) | Flooding group of the flows | - |
| \(0.6[g d_i(\rho_L - \rho_v)]^{1/4}\) | Flooding limit | - |
| \(\text{ratio}\) | Flows as a share of the flooding limit | - |
| \(n_{t,min}\) | Fewest tubes that avoid flooding | - |
Method and standards
Empirical flooding limit for counter-current two-phase flow in vertical tubes.
Where it is used
- Reflux (knock-back) condensers on columns.
- Vent condensers with returning condensate.
Common mistakes
- Using the distillate rate as the vapour rate.
- Checking at the top of the tubes, where flows are smallest.
Assumptions and limits
- Vertical tubes, vapour up and condensate down; rough guide only.
References
- Counter-current flooding criterion [u_v^½ ρ_v^¼ + u_L^½ ρ_L^¼] < 0.6[g d_i(ρ_L − ρ_v)]^¼
Questions and answers
Where is flooding most likely?
At the bottom of the tubes, where all the vapour enters and all the condensate leaves.
How do I find the flows?
Vapour = (R + 1) × distillate and condensate = R × distillate for a total reflux condenser with reflux ratio R.
What do the defaults represent?
An illustrative column top: 4 kg/s of vapour at 3 kg/m³ rising and 3 kg/s of condensate at 780 kg/m³ falling through 300 tubes of 40 mm bore.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 12.10.3, eq. 12.55 and Example 12.6