Kettle Reboiler Bundle: Boiling Coefficient and Critical Heat Flux

Bundle boiling coefficient from the single-tube nucleate coefficient with Palen's bundle factor and natural convection, and the bundle critical heat flux.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Small kettle: 120 tubes 3/4 in on 15/16 in triangular, 0.35 m bundleLarge vaporiser 1,800 tubes 1 in on 1.25 in square, 1.6 m bundle

Accepted: 10 to 100,000 W/(m²·K)
Accepted: 0 to 5,000 W/(m²·K)
Accepted: 50 to 5,000 mm
Accepted: 5 to 100 mm
Accepted: 6 to 150 mm
Accepted: 1 to 10,000
Accepted: 1 to 10,000 kW/m²

Results

Palen's bundle factor allows for the vapour-driven circulation that raises the average coefficient in a bundle; the bundle CHF is far lower than that of a single tube because vapour blankets the upper tubes. Design heat fluxes are usually kept well below the bundle CHF.

Bundle boiling factor2.3025
Bundle boiling coefficient9,210.2W/(m²·K)
Bundle geometry parameter0.034996
Bundle CHF factor0.10849
Bundle critical heat flux54.243kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Small kettle: 120 tubes 3/4 in on 15/16 in triangular, 0.35 m bundle. The inputs, in the units selected above:

InputValue
Single-tube nucleate boiling coefficient2,500.0 W/(m²·K)
Natural convection coefficient (hydrocarbons about 250)300.00 W/(m²·K)
Bundle diameter350.00 mm
Tube outside diameter19.050 mm
Tube pitch23.800 mm
LayoutTriangular (C₁ = 0.866)
Number of tubes120.00 -
Critical heat flux of a single tube450.00 kW/m²

Applying the formula below gives:

ResultValue
Bundle boiling factor1.5484
Bundle boiling coefficient4,170.9 W/(m²·K)
Bundle geometry parameter0.15311
Bundle CHF factor0.47463
Bundle critical heat flux213.58 kW/m²

Open this example in the calculator and change any input.

Formula

\(h_b = h_{nb}F_b + h_{nc}, \quad F_b = 1 + 0.1\left[\frac{0.785D_b}{C_1(P_T/D_o)^2D_o} - 1\right]^{0.75}\)

\(\psi_b = \frac{D_b}{n_tD_o}, \quad \hat q_{c,bundle} = \hat q_{c,tube}\,\phi_b, \ \phi_b = 3.1\psi_b\ (\psi_b < 0.323)\)

Variables

Symbol Meaning SI unit
\(h_{nb}\) Single-tube nucleate boiling coefficient W/(m²·K)
\(h_{nc}\) Natural convection coefficient (hydrocarbons about 250) W/(m²·K)
\(D_b\) Bundle diameter m
\(D_o\) Tube outside diameter m
\(P_T\) Tube pitch m
\(\text{layout}\) Layout -
\(n_t\) Number of tubes -
\(\hat q_{c,tube}\) Critical heat flux of a single tube W/m²
\(F_b\) Bundle boiling factor -
\(h_b\) Bundle boiling coefficient W/(m²·K)
\(\psi_b\) Bundle geometry parameter -
\(\phi_b\) Bundle CHF factor -
\(\hat q_{c,bundle}\) Bundle critical heat flux W/m²

Method and standards

Palen's bundle boiling corrections.

Where it is used

  • Kettle reboiler and vaporiser design.
  • Checking design heat flux against bundle CHF.

Common mistakes

  • Using single-tube CHF for a bundle.
  • Ignoring natural convection at low superheat.

Assumptions and limits

  • Plain-tube kettle bundles; pure or near-pure fluids.

Questions and answers

Why is the bundle CHF so much lower?

Vapour rising from the lower tubes blankets the upper ones; for large bundles the critical flux can be a fifth of a single tube's.

Where does h_nb come from?

From a single-tube nucleate boiling correlation such as Mostinski or Cooper at the wall superheat.

What do the defaults represent?

An illustrative case: Small kettle: 120 tubes 3/4 in on 15/16 in triangular, 0.35 m bundle. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.2, eqs. 9.19, 9.20 and 9.24 (Palen) and Example 9.4

Related calculators