FireCADCalc

Gas Distribution between Steam and Water (CO₂, O₂, H₂S and others)

Concentration of a dissolved gas in steam from its concentration in boiler or condensate water at a temperature (IAPWS G7-04 distribution constant).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolDeaerator and feedwater system

Inputs

Examples: CO2 at 180 °CO2 at 105 °CH2S at 150 °C

Results

Mass ratio equals the mole ratio for dilute gases in water (same solvent on both sides).

Distribution constant y/x56,587
Gas in the steam (by mass)1,131,732ppb
Saturation pressure1.2090bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: CO2 at 180 °C. The inputs, in the units selected above:

InputValue
GasCarbon dioxide CO₂
Saturation temperature180.00 °C
Gas in the water (by mass)50.000 ppb

Applying the formula below gives:

ResultValue
Distribution constant y/x584.02
Gas in the steam (by mass)29,201 ppb
Saturation pressure10.026 bar

Open this example in the calculator and change any input.

Formula

\(K_D = \frac{y}{x}, \quad w_s = K_D w_w\)

Variables

Symbol Meaning SI unit
\(\text{gas}\) Gas -
\(T\) Saturation temperature K
\(w_w\) Gas in the water (by mass) -
\(K_D\) Distribution constant y/x -
\(w_s\) Gas in the steam (by mass) -
\(p_{sat}\) Saturation pressure Pa

Method and standards

IAPWS G7-04.

Where it is used

  • Condensate corrosion studies.
  • Deaerator and degasser design.

Common mistakes

  • Using K_D at the wrong temperature.

Assumptions and limits

  • Equilibrium, dilute.
  • For CO₂ and H₂S the water figure is the molecular gas only, not total CO₂ or sulphide: bicarbonate, carbonate and HS⁻ do not distribute to steam by K_D.
  • A result above 100 % gas in the steam is rejected; above 1 % the dilute-solution assumption no longer holds and a warning is given.

References

  • IAPWS G7-04
  • Guideline on the Henry's Constant and Vapor-Liquid Distribution Constant for Gases in H₂O and D₂O at High Temperatures (2004)

Questions and answers

Why does CO₂ end up in condensate?

Bicarbonate breaks down in the boiler; the CO₂ goes with the steam and redissolves as carbonic acid where steam condenses.

K_D near the critical point?

It falls toward 1: gases share almost equally between steam and water.

Ammonia and amines?

Not covered by this guideline; their distribution ratios come from other data.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.