Worked example
Example: Ideal: 66 bar(a) / 485 °C, heater 4 bar(a), 0.1 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet steam pressure (absolute) | 66.000 bar |
| Inlet steam condition | Superheated at the temperature below |
| Inlet steam temperature (superheated only) | 485.00 °C |
| Feedwater heater (bleed) pressure (absolute) | 4.0000 bar |
| Condenser pressure (absolute) | 10.000 kPa |
| Turbine isentropic efficiency (each section) | 100.00 % |
| Pump isentropic efficiency (condensate and feed pumps) | 100.00 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cycle thermal efficiency | 40.980 % |
| Steam bled to the heater, per kg of main steam | 16.504 % |
| Net work per kg of main steam | 1,134.5 kJ/kg |
| Specific steam consumption (per kWh of net shaft work) | 3.1733 kg/kWh |
| Heat added in the boiler | 2,768.3 kJ/kg |
| Turbine exhaust dryness | 81.803 % |
Open this example in the calculator and change any input.
Formula
\(y = \frac{h_f(p_h) - h_{p1}}{h_x - h_{p1}} \qquad w_t = (h_1 - h_x) + (1 - y)(h_x - h_4)\)
\(h_x = h_1 - \eta_t\left[h_1 - h(p_h, s_1)\right] \qquad h_4 = h_x - \eta_t\left[h_x - h(p_2, s_x)\right]\)
\(h_{p1} = h_f(p_2) + w_{p1},\ w_{p1} = \frac{h(p_h, s_f) - h_f(p_2)}{\eta_p} \qquad h_{p2} = h_f(p_h) + w_{p2},\ w_{p2} = \frac{h(p_1, s_f) - h_f(p_h)}{\eta_p}\)
\(w_p = (1 - y)\,w_{p1} + w_{p2} \qquad q_{in} = h_1 - h_{p2} \qquad \eta_{th} = \frac{w_t - w_p}{q_{in}} \qquad SSC = \frac{1}{w_t - w_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | main steam pressure, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated steam | – |
| \(T_1\) | main steam temperature | K |
| \(p_h\) | feed heater (bleed) pressure, absolute | Pa |
| \(p_2\) | condenser pressure, absolute | Pa |
| \(\eta_t\) | turbine isentropic efficiency, each section | – |
| \(\eta_p\) | pump isentropic efficiency (condensate and feed pumps) | – |
| \(\eta_{th}\) | cycle thermal efficiency | – |
| \(y\) | bled steam per kg of main steam | – |
| \(w_{net}\) | net work per kg of main steam | J/kg |
| \(SSC\) | specific steam consumption | kg/J |
| \(q_{in}\) | heat added in the boiler | J/kg |
| \(x_4\) | turbine exhaust dryness | – |
| \(w_t\), \(w_p\) | turbine and pump work | J/kg |
| \(w_{p1}\), \(w_{p2}\) | condensate pump and feed pump work | J/kg |
| \(h_1\), \(h_x\), \(h_4\) | main steam, bleed and exhaust enthalpies | J/kg |
| \(h_{p1}\), \(h_{p2}\) | enthalpy after condensate pump and after feed pump | J/kg |
| \(h_f\) | saturated liquid enthalpy at heater pressure | J/kg |
| \(s_x\), \(s_f\) | entropy at the bleed point, and of the saturated liquid entering each pump | J/(kg·K) |
Method and standards
Rankine cycle with one open (mixing) feedwater heater leaving saturated liquid at heater pressure; isentropic efficiencies on both turbine sections and both pumps; states by FireCAD's IAPWS-IF97.
Where it is used
- Choosing the deaerator pressure of a cogeneration or power plant.
- Teaching and checking regenerative feed heating.
- First heat balances before detailed design.
Common mistakes
- Taking the bled fraction as a share of the condenser flow instead of the main steam.
- Forgetting the second pump after the open heater.
- Using gauge deaerator pressure.
Assumptions and limits
- One open heater, no closed heaters, no reheat; no pressure drops; heater outlet saturated.
- The same η_t is applied to each turbine section, the LP section starting from the actual bleed state. Because of the reheat-factor effect the whole turbine is then slightly more efficient than η_t, so this cycle is not exactly like for like with the simple Rankine page at the same η_t.
- SSC is per kWh of net shaft work, before generator losses.
References
- IAPWS R7-97(2012) IF97
- first and second laws of thermodynamics
Questions and answers
How much does one feed heater gain?
With 66 bar(a) and 485 °C steam, a heater at 4 bar(a) and a 0.1 bar(a) condenser, the ideal cycle rises from 38.5 % to 41.0 %, bleeding 16.5 % of the steam.
Why does bleeding steam raise efficiency?
The bled steam's latent heat warms the feedwater instead of going to the condenser, so the boiler adds heat at a higher average temperature.
Is an open feed heater a deaerator?
In most plants, yes: the deaerator is the open (direct-contact) heater. Closed heaters are calculated with the feedwater heater extraction calculator.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.