Worked example
Example: 30 MW GT, heat rate 10 500 kJ/kWh, exhaust 540 °C, ambient 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas turbine power output | 30.000 MW |
| Gas turbine heat rate (on NCV) | 10,500 kJ/kWh |
| Exhaust temperature | 540.00 °C |
| Ambient (compressor inlet) temperature | 30.000 °C |
| Mean specific heat of the exhaust | 1.1200 kJ/(kg·K) |
| Other losses (generator, lube oil, casing), share of fuel heat | 2.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Exhaust gas flow | 351,366 kg/h |
| Heat in the exhaust above ambient | 55.750 MW |
| Fuel heat input | 87.500 MW |
| Gas turbine efficiency | 34.286 % |
Open this example in the calculator and change any input.
Formula
\(\dot Q_f = P\,HR \qquad \dot Q_{exh} = \dot Q_f\,(1 - \lambda) - P \qquad \dot m_{exh} = \frac{\dot Q_{exh}}{\bar c_p\,(T_{exh} - T_a)} \qquad \eta = \frac{1}{HR}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | power output | W |
| \(HR\) | heat rate on NCV | J/J |
| \(T_{exh}\) | exhaust temperature | K |
| \(T_a\) | ambient temperature | K |
| \(\bar c_p\) | mean exhaust specific heat | J/(kg·K) |
| \(\lambda\) | other losses, share of fuel heat | – |
| \(\dot m_{exh}\) | exhaust flow | kg/s |
| \(\dot Q_{exh}\) | exhaust heat above ambient | W |
| \(\dot Q_f\) | fuel heat input | W |
| \(\eta\) | efficiency | – |
Method and standards
Energy balance: fuel heat leaves as power, other losses and exhaust heat above ambient.
Where it is used
- Early HRSG sizing.
- Cogeneration feasibility with gas turbines.
- Checking exhaust flow from site readings.
Common mistakes
- Mixing ISO and site heat rates.
- Using GCV-based heat rate with NCV assumptions.
- Ignoring the fuel mass in the exhaust (a few per cent).
Assumptions and limits
- Steady state; mean specific heat. The flow is inversely proportional to the c̄_p entered (5 % error in c̄_p gives about 5 % in flow). The default 1120 J/(kg·K) is a round figure for gas turbine exhaust; for a better value compute the mean c_p of your exhaust composition over the temperature range with the gas properties calculator.
References
- Energy balance of the gas turbine
Questions and answers
How much exhaust does a 30 MW gas turbine make?
At a heat rate of 10 500 kJ/kWh it burns 87.5 MW of fuel; after 2 % other losses 55.8 MW leaves in the exhaust, and at 540 °C over 30 °C ambient that is about 98 kg/s.
Why estimate it?
For early HRSG and waste heat studies when the maker's data at site conditions is not yet available.
How accurate is it?
Within a few per cent if the heat rate and exhaust temperature are at the same conditions; use the maker's exhaust flow for design.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.