FireCADCalc

Multistage Turbine: Stage Efficiency and Reheat Factor

Overall internal efficiency and reheat factor of a multistage steam turbine with equal stage pressure ratios and stage efficiency (IF97 expansion).

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Boiler operation engineer (BOE) examinations

Inputs

Examples: 40 bar 400 °C to 2 bar, 8 stages at 75 %Small turbine 20 bar 300 °C to 4 bar, 4 stages at 70 %

Results

The losses of each stage reheat the steam, so later stages have more isentropic drop available: RF > 1.

Sum of stage isentropic drops683.83kJ/kg
Overall isentropic drop648.04kJ/kg
Reheat factor1.0552
Overall internal efficiency η_s × RF79.142%
Exhaust enthalpy2,701.5kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 bar 400 °C to 2 bar, 8 stages at 75 %. The inputs, in the units selected above:

InputValue
Inlet pressure (absolute)40.000 bar
Inlet temperature400.00 °C
Exhaust pressure (absolute)2.0000 bar
Number of stages8.0000 -
Stage efficiency75.000 %

Applying the formula below gives:

ResultValue
Sum of stage isentropic drops683.83 kJ/kg
Overall isentropic drop648.04 kJ/kg
Reheat factor1.0552
Overall internal efficiency η_s × RF79.142 %
Exhaust enthalpy2,701.5 kJ/kg

Open this example in the calculator and change any input.

Formula

\(RF = \frac{\sum \Delta h_{s,i}}{\Delta h_{s,overall}}, \quad \eta_o = \eta_s \cdot RF\)

Variables

Symbol Meaning SI unit
\(p_1\) Inlet pressure (absolute) Pa
\(T_1\) Inlet temperature K
\(p_2\) Exhaust pressure (absolute) Pa
\(n\) Number of stages -
\(\eta_s\) Stage efficiency -
\(\Sigma\Delta h_{s,i}\) Sum of stage isentropic drops J/kg
\(\Delta h_s\) Overall isentropic drop J/kg
\(RF\) Reheat factor -
\(\eta_o\) Overall internal efficiency η_s × RF -
\(h_2\) Exhaust enthalpy J/kg

Method and standards

The expansion is split into n stages with equal pressure ratios; each stage expands at the stage efficiency from the actual state left by the previous stage. The reheat factor is the sum of the stage isentropic drops over the overall isentropic drop, the classical definition in steam turbine texts. States from FireCAD's IAPWS-IF97.

Where it is used

  • Turbine performance studies.
  • BOE examinations.

Common mistakes

  • Assuming equal enthalpy drops per stage.
  • Using the overall isentropic drop per stage.

Assumptions and limits

  • Equal stage pressure ratios and efficiencies.
  • Wet exhaust (dryness below about 88 %) is flagged.
  • The inlet must be superheated or supercritical steam; a liquid inlet is rejected.

References

  • Stage-by-stage expansion with IAPWS-IF97; reheat factor RF = Σ Δh_s
  • stage / Δh_s
  • overall (steam turbine texts)

Questions and answers

40 bar 400 °C to 2 bar in 8 stages at 75 %?

Reheat factor about 1.06: overall efficiency about 79 %, above the 75 % stage efficiency.

Why is overall better than stage efficiency?

Stage losses reappear as heat available to later stages.

Exams?

A classic BOE and turbine question.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.