Worked example
Example: rp 15, 1 200 °C, 86 % / 89 %, 100 kg/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Compressor inlet temperature | 15.000 °C |
| Pressure ratio | 15.000 - |
| Turbine inlet temperature | 1,200.0 °C |
| Compressor isentropic efficiency | 86.000 % |
| Turbine isentropic efficiency | 89.000 % |
| Specific heat of the air and gas | 1.0050 kJ/(kg·K) |
| Ratio of specific heats | 1.4000 - |
| Air mass flow | 360,000 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Compressor outlet temperature | 406.29 °C |
| Turbine outlet (exhaust) temperature | 493.70 °C |
| Compressor work | 393.25 kJ/kg |
| Turbine work | 709.84 kJ/kg |
| Net work | 316.59 kJ/kg |
| Heat added | 797.68 kJ/kg |
| Thermal efficiency | 39.689 % |
| Ideal (isentropic) cycle efficiency | 53.871 % |
| Back-work ratio w_c / w_t | 55.400 % |
| Net power | 31.659 MW |
Open this example in the calculator and change any input.
Formula
\(T_2 = T_1 + \frac{T_1 (r_p^{(\gamma-1)/\gamma} - 1)}{\eta_c}, \quad T_4 = T_3 - \eta_t\, T_3 \left(1 - r_p^{-(\gamma-1)/\gamma}\right)\)
\(w_c = c_p (T_2 - T_1), \quad w_t = c_p (T_3 - T_4), \quad \eta = \frac{w_t - w_c}{c_p (T_3 - T_2)}\)
\(\eta_{ideal} = 1 - r_p^{-(\gamma-1)/\gamma}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Compressor inlet temperature | K |
| \(r_p\) | Pressure ratio | - |
| \(T_3\) | Turbine inlet temperature | K |
| \(\eta_c\) | Compressor isentropic efficiency | - |
| \(\eta_t\) | Turbine isentropic efficiency | - |
| \(c_p\) | Specific heat of the air and gas | J/(kg·K) |
| \(\gamma\) | Ratio of specific heats | - |
| \(\dot m\) | Air mass flow | kg/s |
| \(T_2\) | Compressor outlet temperature | K |
| \(T_4\) | Turbine outlet (exhaust) temperature | K |
| \(w_c\) | Compressor work | J/kg |
| \(w_t\) | Turbine work | J/kg |
| \(w_{net}\) | Net work | J/kg |
| \(q_{in}\) | Heat added | J/kg |
| \(\eta\) | Thermal efficiency | - |
| \(\eta_{ideal}\) | Ideal (isentropic) cycle efficiency | - |
| \(BWR\) | Back-work ratio w_c / w_t | - |
| \(P\) | Net power | W |
Method and standards
The air-standard Brayton cycle with constant specific heats: isentropic compression and expansion corrected by the component isentropic efficiencies, heat added at constant pressure.
Where it is used
- Teaching and first estimates of gas turbine performance.
- Seeing how pressure ratio and firing temperature trade off.
- Estimating exhaust temperature for heat recovery.
Common mistakes
- Applying the ideal efficiency to a real machine.
- Using one cp for air and hot gas when accuracy matters (use the gas properties calculator).
- Mixing pressure ratio with pressure difference.
Assumptions and limits
- Air-standard: no fuel mass, no pressure losses, constant cp and γ.
- No cooling air or blade cooling losses.
- One c_p and γ for air and hot gas: at 1 200 °C the gas has c_p about 1.15–1.2 kJ/(kg·K) and γ about 1.33, so a real machine differs materially. A note appears if c_p and γ imply a gas constant far from air.
References
- Air-standard Brayton cycle (Çengel and Boles, Thermodynamics: An Engineering Approach, ch. 9)
Questions and answers
What efficiency does a pressure ratio of 15 give?
With 1 200 °C at the turbine inlet and 86 % / 89 % component efficiencies, 39.7 %; the ideal cycle at the same ratio gives 53.9 %.
What is the back-work ratio?
The share of turbine work used by the compressor: 55 % in the example. It is why component efficiencies matter so much in gas turbines.
Why is the exhaust so hot?
Expansion ends at about atmospheric pressure, so the exhaust leaves at 400–600 °C, which a heat recovery boiler can use.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.