FireCADCalc

Steam Turbine Power Output

Power of a back-pressure or condensing steam turbine from the steam flow, inlet conditions, exhaust pressure and efficiencies (IAPWS-IF97).

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Steam turbine

Inputs

Examples: 10 t/h, 45 bar(a) / 400 °C to 4 bar(a) back pressure50 t/h, 66 bar(a) / 485 °C to 0.1 bar(a) condensing5 t/h, 17.5 bar(a) saturated to 3 bar(a)

Results

Electrical power1,080.8kW
Turbine shaft power1,137.6kW
Exhaust temperature169.50°C
Exhaust dryness (1 = dry or superheated)100.00%
Inlet enthalpy3,205.6kJ/kg
Exhaust enthalpy2,796.0kJ/kg
Isentropic exhaust enthalpy2,659.5kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h, 45 bar(a) / 400 °C to 4 bar(a) back pressure. The inputs, in the units selected above:

InputValue
Steam flow10,000 kg/h
Inlet steam pressure (absolute)45.000 bar
Inlet steam conditionSuperheated at the temperature below
Inlet steam temperature (superheated only)400.00 °C
Exhaust pressure (absolute)400.00 kPa
Turbine isentropic efficiency75.000 %
Gearbox and generator efficiency95.000 %

Applying the formula below gives:

ResultValue
Electrical power1,080.8 kW
Turbine shaft power1,137.6 kW
Exhaust temperature169.50 °C
Exhaust dryness (1 = dry or superheated)100.00 %
Inlet enthalpy3,205.6 kJ/kg
Exhaust enthalpy2,796.0 kJ/kg
Isentropic exhaust enthalpy2,659.5 kJ/kg

Open this example in the calculator and change any input.

Formula

\(h_{2s} = h(p_2, s_1) \qquad h_2 = h_1 - \eta_i\,(h_1 - h_{2s})\)

\(P_{sh} = \dot m_s\,(h_1 - h_2) \qquad P_{el} = \eta_g\,P_{sh} \qquad T_2,\ x_2 = f(p_2, h_2)\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam flow kg/s
\(p_1\) inlet pressure, absolute Pa
\(\text{state}\) dry saturated or superheated inlet –
\(T_1\) inlet temperature (superheated) K
\(p_2\) exhaust pressure, absolute Pa
\(\eta_i\) turbine isentropic efficiency –
\(\eta_g\) gearbox and generator efficiency –
\(P_{el}\) electrical power W
\(P_{sh}\) turbine shaft power W
\(T_2\) exhaust temperature K
\(x_2\) exhaust dryness fraction –
\(h_1\) inlet enthalpy J/kg
\(h_2\) actual exhaust enthalpy J/kg
\(h_{2s}\) isentropic exhaust enthalpy J/kg
\(s_1\) inlet entropy J/(kg·K)

Method and standards

Steady-flow energy balance across the turbine with the isentropic efficiency definition; inlet and exhaust states, including wet steam, from FireCAD's IAPWS-IF97 (backward equations h(p,s) and T(p,h)).

Where it is used

  • Sizing back-pressure turbines in sugar mills, paper mills and process plants that need low-pressure steam.
  • Checking the output of an existing turbo-generator from its steam flow.
  • Feasibility studies for cogeneration and captive power.

Common mistakes

  • Using gauge pressures: both pressures must be absolute, and condenser pressure is far below atmospheric.
  • Taking the isentropic drop as the actual drop: real turbines make only part of it (the isentropic efficiency).
  • Ignoring gland leakage, bleed and dummy-piston steam that pass through the meter but do little work.

Assumptions and limits

  • Single expansion, no extraction; steady flow; kinetic and potential energy changes neglected.
  • Efficiencies are constant at the given load.

References

  • IAPWS R7-97(2012) IF97
  • first law of thermodynamics (steady-flow energy equation)

Questions and answers

How much power does a steam turbine make?

Steam flow times the enthalpy drop times the efficiencies. 10 t/h at 45 bar(a) and 400 °C expanding to 4 bar(a) with 75 % isentropic efficiency drops 410 kJ/kg and gives 1.08 MW at the generator (95 %); the exhaust leaves at 170 °C, still superheated.

What isentropic efficiency should I use?

The turbine maker's figure for your machine and load. As a rough guide only (not from a cited source), small single-stage back-pressure turbines are well below multistage industrial turbines, and large utility turbines are higher still.

How do I find the steam for a given power?

Use the steam rate calculator, which gives kg/kWh and the steam flow for the output you want.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.