Worked example
Example: 10 t/h, 45 bar(a) / 400 °C to 4 bar(a) back pressure. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 10,000 kg/h |
| Inlet steam pressure (absolute) | 45.000 bar |
| Inlet steam condition | Superheated at the temperature below |
| Inlet steam temperature (superheated only) | 400.00 °C |
| Exhaust pressure (absolute) | 400.00 kPa |
| Turbine isentropic efficiency | 75.000 % |
| Gearbox and generator efficiency | 95.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Electrical power | 1,080.8 kW |
| Turbine shaft power | 1,137.6 kW |
| Exhaust temperature | 169.50 °C |
| Exhaust dryness (1 = dry or superheated) | 100.00 % |
| Inlet enthalpy | 3,205.6 kJ/kg |
| Exhaust enthalpy | 2,796.0 kJ/kg |
| Isentropic exhaust enthalpy | 2,659.5 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(h_{2s} = h(p_2, s_1) \qquad h_2 = h_1 - \eta_i\,(h_1 - h_{2s})\)
\(P_{sh} = \dot m_s\,(h_1 - h_2) \qquad P_{el} = \eta_g\,P_{sh} \qquad T_2,\ x_2 = f(p_2, h_2)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | steam flow | kg/s |
| \(p_1\) | inlet pressure, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated inlet | – |
| \(T_1\) | inlet temperature (superheated) | K |
| \(p_2\) | exhaust pressure, absolute | Pa |
| \(\eta_i\) | turbine isentropic efficiency | – |
| \(\eta_g\) | gearbox and generator efficiency | – |
| \(P_{el}\) | electrical power | W |
| \(P_{sh}\) | turbine shaft power | W |
| \(T_2\) | exhaust temperature | K |
| \(x_2\) | exhaust dryness fraction | – |
| \(h_1\) | inlet enthalpy | J/kg |
| \(h_2\) | actual exhaust enthalpy | J/kg |
| \(h_{2s}\) | isentropic exhaust enthalpy | J/kg |
| \(s_1\) | inlet entropy | J/(kg·K) |
Method and standards
Steady-flow energy balance across the turbine with the isentropic efficiency definition; inlet and exhaust states, including wet steam, from FireCAD's IAPWS-IF97 (backward equations h(p,s) and T(p,h)).
Where it is used
- Sizing back-pressure turbines in sugar mills, paper mills and process plants that need low-pressure steam.
- Checking the output of an existing turbo-generator from its steam flow.
- Feasibility studies for cogeneration and captive power.
Common mistakes
- Using gauge pressures: both pressures must be absolute, and condenser pressure is far below atmospheric.
- Taking the isentropic drop as the actual drop: real turbines make only part of it (the isentropic efficiency).
- Ignoring gland leakage, bleed and dummy-piston steam that pass through the meter but do little work.
Assumptions and limits
- Single expansion, no extraction; steady flow; kinetic and potential energy changes neglected.
- Efficiencies are constant at the given load.
References
- IAPWS R7-97(2012) IF97
- first law of thermodynamics (steady-flow energy equation)
Questions and answers
How much power does a steam turbine make?
Steam flow times the enthalpy drop times the efficiencies. 10 t/h at 45 bar(a) and 400 °C expanding to 4 bar(a) with 75 % isentropic efficiency drops 410 kJ/kg and gives 1.08 MW at the generator (95 %); the exhaust leaves at 170 °C, still superheated.
What isentropic efficiency should I use?
The turbine maker's figure for your machine and load. As a rough guide only (not from a cited source), small single-stage back-pressure turbines are well below multistage industrial turbines, and large utility turbines are higher still.
How do I find the steam for a given power?
Use the steam rate calculator, which gives kg/kWh and the steam flow for the output you want.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.