Worked example
Example: 66 bar(a) / 485 °C to 0.1 bar(a), 82 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet steam pressure (absolute) | 66.000 bar |
| Inlet steam condition | Superheated at the temperature below |
| Inlet steam temperature (superheated only) | 485.00 °C |
| Exhaust pressure (absolute) | 10.000 kPa |
| Turbine isentropic efficiency | 82.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Exhaust dryness fraction (1 = dry or superheated) | 91.067 % |
| Exhaust moisture (wetness) | 8.9328 % |
| Dryness after isentropic expansion | 81.803 % |
| Exhaust temperature | 45.808 °C |
| Exhaust enthalpy | 2,370.2 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(h_2 = h_1 - \eta_i\left[h_1 - h(p_2, s_1)\right] \qquad x_2 = \frac{h_2 - h_f}{h_g - h_f} \qquad y_2 = 1 - x_2 \qquad x_{2s} = \frac{s_1 - s_f}{s_g - s_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | inlet pressure, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated inlet | – |
| \(T_1\) | inlet temperature (superheated) | K |
| \(p_2\) | exhaust pressure, absolute | Pa |
| \(\eta_i\) | turbine isentropic efficiency | – |
| \(x_2\) | exhaust dryness fraction | – |
| \(y_2\) | exhaust moisture | – |
| \(x_{2s}\) | dryness after isentropic expansion | – |
| \(T_2\) | exhaust temperature | K |
| \(h_2\) | exhaust enthalpy | J/kg |
| \(h_1\), \(s_1\) | inlet enthalpy and entropy | J/kg, J/(kg·K) |
| \(h_f\), \(h_g\), \(s_f\), \(s_g\) | saturated liquid and vapour enthalpy and entropy at \(p_2\) | J/kg, J/(kg·K) |
Method and standards
Exhaust state from the isentropic-efficiency expansion; dryness from saturation properties at the exhaust pressure, all by FireCAD's IAPWS-IF97. A superheated exhaust shows dryness 1.
Where it is used
- Checking blade erosion risk when inlet temperature or condenser vacuum changes.
- Condenser heat balances, which need the exhaust dryness.
- Choosing inlet superheat or reheat for a new turbine.
Common mistakes
- Using the isentropic dryness as the real one.
- Taking the condenser pressure as the last-stage exit pressure when the exhaust hood loses pressure.
- Using gauge pressures.
Assumptions and limits
- One expansion with constant efficiency; equilibrium wet steam (no supercooling).
References
- IAPWS R7-97(2012) IF97
Questions and answers
How wet is turbine exhaust steam?
Expanding from 66 bar(a) and 485 °C to 0.1 bar(a) with 82 % efficiency, the exhaust is 91.1 % dry, 8.9 % moisture. An ideal (isentropic) turbine would leave it only 81.8 % dry.
What wetness is allowed?
The turbine maker sets the limit; this page warns below 88 % dryness (12 % moisture), a commonly used level rather than a sourced limit. More moisture erodes the last-stage blades. Reheat or higher inlet superheat keeps it down.
Why is the real exhaust drier than the ideal one?
Turbine losses turn into heat in the steam, which re-evaporates some of the moisture.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.