Worked example
Example: Lower inlet pressure. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Design flow | 100.00 t/h |
| Design inlet pressure (absolute) | 87.000 bar |
| Design inlet temperature | 515.00 °C |
| Design outlet pressure (absolute) | 2.5000 bar |
| New inlet pressure (absolute) | 80.000 bar |
| New inlet temperature | 510.00 °C |
| New outlet pressure (absolute) | 2.5000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow at the new conditions | 92.055 t/h |
| Flow ratio | 92.055 % |
Open this example in the calculator and change any input.
Formula
\(\frac{\dot m}{\dot m_0} = \sqrt{\frac{p_{in}^2 - p_{out}^2}{p_{in,0}^2 - p_{out,0}^2}}\sqrt{\frac{p_{in,0}v_{in,0}}{p_{in}v_{in}}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_0\) | Design flow | kg/s |
| \(p_{in,0}\) | Design inlet pressure (absolute) | Pa |
| \(T_{in,0}\) | Design inlet temperature | K |
| \(p_{out,0}\) | Design outlet pressure (absolute) | Pa |
| \(p_{in}\) | New inlet pressure (absolute) | Pa |
| \(T_{in}\) | New inlet temperature | K |
| \(p_{out}\) | New outlet pressure (absolute) | Pa |
| \(\dot m\) | Flow at the new conditions | kg/s |
| \(\dot m/\dot m_0\) | Flow ratio | - |
Method and standards
Stodola's ellipse (cone) law for a group of turbine stages: with fixed geometry the flow is proportional to √((p_in² − p_out²)/(p_in v_in)), so the flow at new conditions follows from a known design point. Inlet specific volumes from FireCAD's IAPWS-IF97.
Where it is used
- Turbine performance monitoring.
- Off-design studies.
Common mistakes
- Using gauge pressures in the squares.
Assumptions and limits
- Fixed stage geometry.
- Both inlet states must be superheated (or supercritical) steam; a liquid inlet state is rejected.
References
- Stodola's ellipse (cone) law ṁ ∝ √((p_in² − p_out²)/(p_in v_in)); specific volumes from IAPWS-IF97
Questions and answers
What does the ellipse law say?
A group of turbine stages behaves like a nozzle: flow follows inlet pressure and density, softened by the outlet pressure.
Use?
Predicting extraction pressures and flows at part load, or checking for a damaged or fouled stage group.
Choked groups?
When the outlet is much lower than the inlet, flow is nearly proportional to p_in/√(p_in v_in).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.