Worked example
Example: 550,000 lb/h exhaust at 14 % O2, 30 MW. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Exhaust gas flow | 249.48 t/h |
| Oxygen in the exhaust (by volume, wet basis) | 14.000 % |
| Exhaust molar mass | 29.500 kg/kmol |
| Fuel (Ganapathy Table 2.4: dry air per MMBtu fired, lb) | Natural gas (730) |
| Fuel LHV/HHV ratio | 90.000 % |
| Planned firing (LHV) | 30.000 MW |
| Exhaust specific heat | 1.1300 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Equivalent air in the exhaust | 164.72 t/h |
| Maximum heat that can be fired (LHV) | 131.21 MW |
| Planned firing as a share of the maximum | 22.863 % |
| Gas temperature rise from the planned firing | 383.10 K |
Open this example in the calculator and change any input.
Formula
\(W_a = \frac{W_g\,O \times 32}{0.23\,M_g}, \quad Q_{max} = W_a\,\frac{LHV}{A\,HHV}, \quad \Delta T = \frac{Q}{W_g c_{pg}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W_g\) | Exhaust gas flow | kg/s |
| \(O\) | Oxygen in the exhaust (by volume, wet basis) | - |
| \(M_g\) | Exhaust molar mass | kg/kmol |
| \(A\) | Fuel (Ganapathy Table 2.4: dry air per MMBtu fired, lb) | - |
| \(LHV/HHV\) | Fuel LHV/HHV ratio | - |
| \(Q\) | Planned firing (LHV) | W |
| \(c_{pg}\) | Exhaust specific heat | J/(kg·K) |
| \(W_a\) | Equivalent air in the exhaust | kg/s |
| \(Q_{max}\) | Maximum heat that can be fired (LHV) | W |
| \(Q/Q_{max}\) | Planned firing as a share of the maximum | - |
| \(\Delta T\) | Gas temperature rise from the planned firing | K |
Method and standards
Ganapathy's oxygen balance; LHV/(A·HHV) ≈ 0.00124 for gas and oil.
Where it is used
- HRSG duct burner sizing.
- Checking supplementary firing schemes.
Common mistakes
- Firing to zero oxygen.
- Using HHV heat input with LHV limits.
Assumptions and limits
- Exhaust oxygen known; complete combustion.
- Exhaust oxygen must be above zero; a planned firing above the maximum is flagged, and its temperature rise then cannot be reached.
- The oxygen is by volume on the wet exhaust, consistent with the wet molar mass M_g in the volume-to-mass conversion.
- Table 2.4 figures are lb of air per MMBtu; the page converts them to SI.
References
- Ganapathy
- Steam Plant Calculations Manual
- 2nd ed. (Marcel Dekker, 1993)
- Q2.27
- Eqs. (22)–(25)
- and Table 2.4
Questions and answers
Why can gas turbine exhaust be fired?
It holds 14–16 % oxygen, enough to burn fuel without fresh air.
How far can it go?
In theory until the oxygen is used; burners need a few per cent left, so firing to about 2,000 °F is a practical limit.
What is 0.23?
The mass fraction of oxygen in air.