Worked example
Example: 100 MW gas turbine at 36 %, 80 % recovery, 33 % steam cycle. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas turbine power | 100.00 MW |
| Gas turbine efficiency (on fuel heat) | 36.000 % |
| Share of the exhaust heat the HRSG recovers | 80.000 % |
| Steam cycle efficiency (power ÷ heat absorbed in the HRSG) | 33.000 % |
| Auxiliary power, share of gross output | 2.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel heat input | 277.78 MW |
| Heat in the gas turbine exhaust | 177.78 MW |
| Heat recovered in the HRSG | 142.22 MW |
| Steam turbine power | 46.933 MW |
| Gross combined cycle output | 146.93 MW |
| Net output | 143.99 MW |
| Gross combined cycle efficiency | 52.896 % |
| Net efficiency | 51.838 % |
| Net heat rate | 6,944.7 kJ/kWh |
Open this example in the calculator and change any input.
Formula
\(Q_F = \frac{P_{GT}}{\eta_{GT}}, \quad Q_{ex} = Q_F - P_{GT}, \quad Q_R = \eta_R\, Q_{ex}, \quad P_{ST} = \eta_{ST}\, Q_R\)
\(\eta_{CC} = \eta_{GT} + (1 - \eta_{GT})\, \eta_R\, \eta_{ST}\)
\(P_n = (P_{GT} + P_{ST})(1 - a), \quad \eta_n = P_n / Q_F, \quad HR_n = Q_F / P_n\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_{GT}\) | Gas turbine power | W |
| \(\eta_{GT}\) | Gas turbine efficiency (on fuel heat) | - |
| \(\eta_R\) | Share of the exhaust heat the HRSG recovers | - |
| \(\eta_{ST}\) | Steam cycle efficiency (power ÷ heat absorbed in the HRSG) | - |
| \(a\) | Auxiliary power, share of gross output | - |
| \(Q_F\) | Fuel heat input | W |
| \(Q_{ex}\) | Heat in the gas turbine exhaust | W |
| \(Q_R\) | Heat recovered in the HRSG | W |
| \(P_{ST}\) | Steam turbine power | W |
| \(P_g\) | Gross combined cycle output | W |
| \(P_n\) | Net output | W |
| \(\eta_{CC}\) | Gross combined cycle efficiency | - |
| \(\eta_n\) | Net efficiency | - |
| \(HR_n\) | Net heat rate | J/J |
Method and standards
An energy balance of the topping and bottoming cycles: the gas turbine's fuel heat less its power is the exhaust heat; the HRSG recovers a share of it; the steam cycle converts that share at its own efficiency.
Where it is used
- First estimate of a combined cycle or cogeneration conversion.
- Comparing gas turbine choices for the same steam cycle.
- Explaining the gain from adding a steam turbine to an open-cycle plant.
Common mistakes
- Using the steam cycle efficiency on fuel heat instead of heat absorbed in the HRSG.
- Using lower and higher heating values together.
- Forgetting the gas turbine output falls with HRSG back pressure.
Assumptions and limits
- Steady full load; no supplementary firing.
- Gas turbine losses other than exhaust are counted as exhaust heat.
- Heating value basis follows the gas turbine efficiency entered, usually LHV; efficiencies and heat rate are on that basis.
References
- Combined cycle energy balance (Kehlhofer, Hannemann, Stirnimann and Rukes, Combined-Cycle Gas & Steam Turbine Power Plants, 3rd ed., PennWell, 2009)
Questions and answers
What efficiency does a 36 % gas turbine reach in combined cycle?
With 80 % of its exhaust heat recovered and a 33 % steam cycle, 52.9 % gross: the steam turbine adds about 47 MW to a 100 MW gas turbine.
Why is combined cycle so efficient?
The gas turbine rejects its heat at 500–600 °C; the steam cycle uses that heat instead of fuel, so η = η_GT + (1 − η_GT) η_R η_ST.
Is supplementary firing included?
No. Duct firing adds fuel at a lower marginal efficiency; use the HRSG supplementary firing calculator for that.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.