Worked example
Example: Double acting, 3 bar mep, 250 x 350 mm, 200 rpm, 40 mm rod, 25 kW brake. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean effective pressure (from the indicator diagram) | 3.0000 bar |
| Cylinder bore | 250.00 mm |
| Stroke | 350.00 mm |
| Speed | 200.00 rpm |
| Cylinder | Double acting |
| Piston rod diameter (double acting) | 40.000 mm |
| Brake power measured (for mechanical efficiency) | 25.000 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Indicated power, cover (head) end | 17.181 kW |
| Indicated power, crank end | 16.741 kW |
| Indicated power | 33.921 kW |
| Mechanical efficiency (BP/IP for an engine, IP/BP for a compressor) | 73.700 % |
| Mean piston speed 2 L N | 2.3333 m/s |
Open this example in the calculator and change any input.
Formula
\(IP = p_m\, L\, A\, N \quad \text{per working side}\)
\(IP = p_m L N \left[A + \left(A - \frac{\pi d_r^2}{4}\right)\right]\ (\text{double acting}), \quad \eta_m = \frac{BP}{IP}\ \text{(engine)},\ \frac{IP}{BP}\ \text{(compressor)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_m\) | Mean effective pressure (from the indicator diagram) | Pa |
| \(D\) | Cylinder bore | m |
| \(L\) | Stroke | m |
| \(N\) | Speed | 1/s |
| \(\text{acting}\) | Cylinder | - |
| \(d_r\) | Piston rod diameter (double acting) | m |
| \(BP\) | Brake power measured (for mechanical efficiency) | W |
| \(IP_h\) | Indicated power, cover (head) end | W |
| \(IP_c\) | Indicated power, crank end | W |
| \(IP\) | Indicated power | W |
| \(\eta_m\) | Mechanical efficiency (BP/IP for an engine, IP/BP for a compressor) | - |
| \(V_p\) | Mean piston speed 2 L N | m/s |
Method and standards
Work per cycle is the indicator diagram area, p_m × L × A; multiplied by the working strokes per second.
Worked example
A double-acting steam engine has a 250 mm bore, 350 mm stroke and 40 mm rod; at 200 rpm the mean effective pressure is 3 bar and the brake power 25 kW.
- A = π × 0.25²/4 = 0.04909 m²; rod area 0.00126 m²
- Cover end = 3×10⁵ × 0.35 × 0.04909 × 200/60 = 17.18 kW
- Crank end = 3×10⁵ × 0.35 × 0.04783 × 200/60 = 16.74 kW
- IP = 33.9 kW; η_m = 25 / 33.9 = 73.7 %
Where it is used
- Boiler and engine-room examinations.
- Reciprocating compressor and pump power checks.
- Steam engine testing in heritage and teaching.
Common mistakes
- Using rpm instead of revolutions per second.
- Doubling for double acting without deducting the rod.
- Using gauge pressure readings at a point instead of the mean effective pressure.
Assumptions and limits
- One cylinder; multiply for several.
- Mean effective pressure from the indicator diagram, taken equal for the cover and crank ends; use the mean of both diagrams when they differ.
- When the brake (shaft) power is above the indicated power the machine is taken as a compressor and η_m = IP/BP; for an engine that reading would be an error.
References
- Indicated power from the indicator diagram (textbook)
Questions and answers
What is the indicated power of a double-acting engine: 3 bar mep, 250 mm bore, 350 mm stroke, 200 rpm, 40 mm rod?
Cover end 17.2 kW, crank end 16.7 kW (the rod takes some area), total 33.9 kW. With 25 kW brake power the mechanical efficiency is 73.7 %.
Why does double acting nearly double the power?
Steam works on both sides of the piston, but the crank side loses the area of the piston rod.
Does it apply to compressors?
Yes; for a compressor IP is the power to the gas, and the shaft power is IP divided by the mechanical efficiency.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.