FireCADCalc

Rankine Cycle Efficiency Calculator

Thermal efficiency, net work, back work ratio and specific steam consumption of a simple Rankine steam cycle with turbine and pump efficiencies (IAPWS-IF97).

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)BoilerSteam turbinePumpBoiler attendant and boiler operator examinationsBoiler operation engineer (BOE) examinations

Inputs

Examples: Ideal: 66 bar(a) / 485 °C, condenser 0.1 bar(a)Real: 66 bar(a) / 485 °C, 0.1 bar(a), turbine 85 %, pump 75 %Saturated 40 bar(a), 0.15 bar(a), 80 % / 70 %

Results

Cycle thermal efficiency32.638%
Net work per kg of steam1,037.6kJ/kg
Specific steam consumption (per kWh of net shaft work)3.4696kg/kWh
Turbine exhaust dryness (state 2)89.523%
Turbine work1,046.5kJ/kg
Pump work8.8644kJ/kg
Heat added in the boiler3,179.1kJ/kg
Back work ratio0.84709%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ideal: 66 bar(a) / 485 °C, condenser 0.1 bar(a). The inputs, in the units selected above:

InputValue
Inlet steam pressure (absolute)66.000 bar
Inlet steam conditionSuperheated at the temperature below
Inlet steam temperature (superheated only)485.00 °C
Condenser pressure (absolute)10.000 kPa
Turbine isentropic efficiency100.00 %
Feed pump isentropic efficiency100.00 %

Applying the formula below gives:

ResultValue
Cycle thermal efficiency38.490 %
Net work per kg of steam1,224.5 kJ/kg
Specific steam consumption (per kWh of net shaft work)2.9400 kg/kWh
Turbine exhaust dryness (state 2)81.803 %
Turbine work1,231.1 kJ/kg
Pump work6.6483 kJ/kg
Heat added in the boiler3,181.3 kJ/kg
Back work ratio0.54002 %

Open this example in the calculator and change any input.

Formula

\(w_t = h_1 - h_2,\quad h_2 = h_1 - \eta_t\,\left[h_1 - h(p_2, s_1)\right] \qquad w_p = \frac{h(p_1, s_3) - h_3}{\eta_p}\)

\(q_{in} = h_1 - (h_3 + w_p) \qquad w_{net} = w_t - w_p \qquad \eta_{th} = \frac{w_{net}}{q_{in}} \qquad BWR = \frac{w_p}{w_t} \qquad SSC = \frac{1}{w_{net}}\)

Variables

Symbol Meaning SI unit
\(p_1\) boiler (turbine inlet) pressure, absolute Pa
\(\text{state}\) dry saturated or superheated steam –
\(T_1\) turbine inlet temperature K
\(p_2\) condenser pressure, absolute Pa
\(\eta_t\) turbine isentropic efficiency –
\(\eta_p\) pump isentropic efficiency –
\(\eta_{th}\) cycle thermal efficiency –
\(w_{net}\) net work per kg J/kg
\(SSC\) specific steam consumption, per unit of net shaft work (before generator losses) kg/J
\(x_2\) turbine exhaust dryness (state 2) –
\(w_t\) turbine work J/kg
\(w_p\) pump work J/kg
\(q_{in}\) heat added in the boiler J/kg
\(BWR\) back work ratio –
\(h_1\), \(h_2\) turbine inlet and exhaust enthalpy J/kg
\(h_3\), \(s_3\) saturated liquid enthalpy and entropy at the condenser J/kg, J/(kg·K)
\(s_1\) turbine inlet entropy J/(kg·K)

Method and standards

Ideal Rankine cycle with isentropic efficiencies on the turbine and the pump; all states (including the compressed liquid after the pump) by FireCAD's IAPWS-IF97. Pressure drops and heat losses in pipes are neglected.

Where it is used

  • Teaching and checking steam-cycle fundamentals.
  • First estimates of a power plant's efficiency for chosen steam conditions.
  • Comparing steam conditions before a detailed heat balance.

Common mistakes

  • Using gauge pressures for boiler and condenser.
  • Taking the condensate as cold water instead of saturated liquid at condenser pressure.
  • Forgetting that real plants also lose heat in the boiler (boiler efficiency) and in auxiliaries.

Assumptions and limits

  • No reheat or feed heating; saturated liquid leaving the condenser; no pressure drops.
  • States: 1 turbine inlet, 2 turbine exhaust, 3 condenser outlet (saturated liquid), then the pump outlet.
  • SSC is per kWh of net shaft work; divide by the generator efficiency for steam per kWh of electricity.

References

  • IAPWS R7-97(2012) IF97
  • first and second laws of thermodynamics

Questions and answers

What is the efficiency of a Rankine cycle?

Net work over heat added. With steam at 66 bar(a) and 485 °C and a condenser at 0.1 bar(a), the ideal cycle is 38.5 % efficient, with exhaust 81.8 % dry; with an 85 % turbine and a 75 % pump it falls to 32.6 %.

Why is the pump work so small?

Pumping liquid takes little work because its volume is tiny; here it is under 1 % of the turbine work (the back work ratio). Gas turbines, which compress gas, have back work ratios of 40–60 %.

How do I raise the efficiency?

Higher steam pressure and temperature, lower condenser pressure, reheat and feed heating. The reheat and regenerative calculators show the last two.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.