Worked example
Example: Ideal: 66 bar(a) / 485 °C, condenser 0.1 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet steam pressure (absolute) | 66.000 bar |
| Inlet steam condition | Superheated at the temperature below |
| Inlet steam temperature (superheated only) | 485.00 °C |
| Condenser pressure (absolute) | 10.000 kPa |
| Turbine isentropic efficiency | 100.00 % |
| Feed pump isentropic efficiency | 100.00 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cycle thermal efficiency | 38.490 % |
| Net work per kg of steam | 1,224.5 kJ/kg |
| Specific steam consumption (per kWh of net shaft work) | 2.9400 kg/kWh |
| Turbine exhaust dryness (state 2) | 81.803 % |
| Turbine work | 1,231.1 kJ/kg |
| Pump work | 6.6483 kJ/kg |
| Heat added in the boiler | 3,181.3 kJ/kg |
| Back work ratio | 0.54002 % |
Open this example in the calculator and change any input.
Formula
\(w_t = h_1 - h_2,\quad h_2 = h_1 - \eta_t\,\left[h_1 - h(p_2, s_1)\right] \qquad w_p = \frac{h(p_1, s_3) - h_3}{\eta_p}\)
\(q_{in} = h_1 - (h_3 + w_p) \qquad w_{net} = w_t - w_p \qquad \eta_{th} = \frac{w_{net}}{q_{in}} \qquad BWR = \frac{w_p}{w_t} \qquad SSC = \frac{1}{w_{net}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | boiler (turbine inlet) pressure, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated steam | – |
| \(T_1\) | turbine inlet temperature | K |
| \(p_2\) | condenser pressure, absolute | Pa |
| \(\eta_t\) | turbine isentropic efficiency | – |
| \(\eta_p\) | pump isentropic efficiency | – |
| \(\eta_{th}\) | cycle thermal efficiency | – |
| \(w_{net}\) | net work per kg | J/kg |
| \(SSC\) | specific steam consumption, per unit of net shaft work (before generator losses) | kg/J |
| \(x_2\) | turbine exhaust dryness (state 2) | – |
| \(w_t\) | turbine work | J/kg |
| \(w_p\) | pump work | J/kg |
| \(q_{in}\) | heat added in the boiler | J/kg |
| \(BWR\) | back work ratio | – |
| \(h_1\), \(h_2\) | turbine inlet and exhaust enthalpy | J/kg |
| \(h_3\), \(s_3\) | saturated liquid enthalpy and entropy at the condenser | J/kg, J/(kg·K) |
| \(s_1\) | turbine inlet entropy | J/(kg·K) |
Method and standards
Ideal Rankine cycle with isentropic efficiencies on the turbine and the pump; all states (including the compressed liquid after the pump) by FireCAD's IAPWS-IF97. Pressure drops and heat losses in pipes are neglected.
Where it is used
- Teaching and checking steam-cycle fundamentals.
- First estimates of a power plant's efficiency for chosen steam conditions.
- Comparing steam conditions before a detailed heat balance.
Common mistakes
- Using gauge pressures for boiler and condenser.
- Taking the condensate as cold water instead of saturated liquid at condenser pressure.
- Forgetting that real plants also lose heat in the boiler (boiler efficiency) and in auxiliaries.
Assumptions and limits
- No reheat or feed heating; saturated liquid leaving the condenser; no pressure drops.
- States: 1 turbine inlet, 2 turbine exhaust, 3 condenser outlet (saturated liquid), then the pump outlet.
- SSC is per kWh of net shaft work; divide by the generator efficiency for steam per kWh of electricity.
References
- IAPWS R7-97(2012) IF97
- first and second laws of thermodynamics
Questions and answers
What is the efficiency of a Rankine cycle?
Net work over heat added. With steam at 66 bar(a) and 485 °C and a condenser at 0.1 bar(a), the ideal cycle is 38.5 % efficient, with exhaust 81.8 % dry; with an 85 % turbine and a 75 % pump it falls to 32.6 %.
Why is the pump work so small?
Pumping liquid takes little work because its volume is tiny; here it is under 1 % of the turbine work (the back work ratio). Gas turbines, which compress gas, have back work ratios of 40–60 %.
How do I raise the efficiency?
Higher steam pressure and temperature, lower condenser pressure, reheat and feed heating. The reheat and regenerative calculators show the last two.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.