HRSG Supplementary (Duct Burner) Firing Fuel

Fuel a duct burner needs to raise gas turbine exhaust from one temperature to another in a supplementary-fired HRSG, from the exhaust flow and NCV.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoilerBurner and furnace

Inputs

Examples: GT exhaust 100 kg/s from 550 to 750 °C, natural gas 47 MJ/kg50 kg/s from 500 to 650 °C, 47 MJ/kg200 kg/s from 580 to 700 °C, 46 MJ/kg, 98 %

Results

Gas turbine exhaust holds about 13–16 % O₂, enough for supplementary firing; check the O₂ left after firing and the duct and liner temperature limits with the burner maker.

Fuel needed1,825.9kg/h
Heat added to the gas23.600MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: GT exhaust 100 kg/s from 550 to 750 °C, natural gas 47 MJ/kg. The inputs, in the units selected above:

InputValue
Exhaust gas flow360,000 kg/h
Mean specific heat of the gas between T₁ and T₂1.1800 kJ/(kg·K)
Gas temperature before the burner550.00 °C
Gas temperature after firing750.00 °C
Net calorific value of the fuel47,000 kJ/kg
Burner (combustion) efficiency99.000 %

Applying the formula below gives:

ResultValue
Fuel needed1,825.9 kg/h
Heat added to the gas23.600 MW

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_g\,c_{p,g}\,(T_2 - T_1) \qquad \dot m_f = \frac{\dot Q}{NCV\,\eta_b}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) exhaust gas flow kg/s
\(c_{p,g}\) mean gas specific heat between T₁ and T₂ J/(kg·K)
\(T_1\) temperature before firing K
\(T_2\) temperature after firing K
\(NCV\) net calorific value of the fuel J/kg
\(\eta_b\) burner efficiency –
\(\dot m_f\) fuel needed kg/s
\(\dot Q\) heat added W

Method and standards

Energy balance of the exhaust with a mean specific heat; the small mass of fuel added is neglected.

Where it is used

  • Sizing duct burners.
  • Fuel budgets of fired HRSGs.
  • Comparing fired and unfired operation.

Common mistakes

  • Using GCV instead of NCV.
  • Forgetting the O₂ left after firing (minimum for stable flames).
  • Firing above the duct liner temperature limit.

Assumptions and limits

  • Constant gas specific heat (the mean between T₁ and T₂); fuel mass neglected.
  • The O₂ left after firing is not calculated (the exhaust analysis and fuel are not inputs): check with the combustion or flue gas calculators, and with the burner maker, that enough O₂ remains for the fired temperature.

References

  • Energy balance of the exhaust gas

Questions and answers

How much gas does a duct burner need?

Raising 100 kg/s of exhaust from 550 to 750 °C takes 23.6 MW; with natural gas of 47 MJ/kg NCV and 99 % burner efficiency that is about 1830 kg/h.

Why can exhaust be fired without fresh air?

Gas turbine exhaust still holds most of its oxygen, about 13–16 %, enough to burn extra fuel.

Why fire at all?

To make more steam, or steam at a higher pressure, than the exhaust alone gives, at an efficiency close to 100 % for the extra fuel.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.