Worked example
Example: Thermic fluid 150 → 280 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Exhaust flow | 11,000 kg/h |
| Exhaust specific heat | 1.1000 kJ/(kg·K) |
| Exhaust in | 450.00 °C |
| Exhaust out | 230.00 °C |
| Liquid specific heat | 2.5000 kJ/(kg·K) |
| Liquid in | 150.00 °C |
| Liquid out | 280.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat transferred | 739.44 kW |
| Liquid flow | 8.1908 t/h |
| Cold-end approach (counter-flow) | 80.000 K |
| Hot-end approach | 170.00 K |
Open this example in the calculator and change any input.
Formula
\(Q = \dot m_gc_{pg}(T_{g1} - T_{g2}), \quad \dot m_l = \frac{Q}{c_{pl}(T_{l2} - T_{l1})}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | Exhaust flow | kg/s |
| \(c_{pg}\) | Exhaust specific heat | J/(kg·K) |
| \(T_{g1}\) | Exhaust in | K |
| \(T_{g2}\) | Exhaust out | K |
| \(c_{pl}\) | Liquid specific heat | J/(kg·K) |
| \(T_{l1}\) | Liquid in | K |
| \(T_{l2}\) | Liquid out | K |
| \(Q\) | Heat transferred | W |
| \(\dot m_l\) | Liquid flow | kg/s |
| \(T_{g2} - T_{l1}\) | Cold-end approach (counter-flow) | K |
| \(T_{g1} - T_{l2}\) | Hot-end approach | K |
Method and standards
Energy balance with approach checks.
Where it is used
- Exhaust heaters on engines, turbines and kilns.
Common mistakes
- A temperature cross.
- Ignoring fluid film temperature limits.
Assumptions and limits
- Counter-flow; no losses. A temperature cross at either end is rejected; a cold-end approach under 20 K gives a warning.
- The acid dew point at the exhaust outlet and the thermic fluid film temperature are not checked.
References
- Energy balances (definitions)
Questions and answers
Why thermic fluid instead of steam?
It reaches 250–300 °C at near-atmospheric pressure, without a pressurised drum.
What approach is practical?
20–40 K at the cold end for finned-tube exhaust heaters.
Is the film temperature a concern?
Yes: check the thermic fluid's film temperature in the hottest rows.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.