FireCADCalc

HRSG Gas Flow from Steam Output (Energy Balance)

Exhaust gas flow through an HRSG back-calculated from measured steam flow and conditions, feedwater and gas temperatures, for performance tests.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Ganapathy Q8.45b: 68,700 lb/h, 500 psig 690 °F, gas 970 → 380 °F (book ~501,300 lb/h)Saturated 10 bar, 12 t/h, 520 → 170 °C

Results

Gas flow in large ducts is hard to measure (3–5 % error per PTC 4.4); the energy balance gives a better figure. Then run an off-design simulation at this flow to judge whether the HRSG meets its guarantee.

Heat to steam and blowdown23,175kW
Gas flow227,445kg/h
Steam per kg of gas0.13701kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy Q8.45b: 68,700 lb/h, 500 psig 690 °F, gas 970 → 380 °F (book ~501,300 lb/h). The inputs, in the units selected above:

InputValue
Steam flow31,162 kg/h
Steam pressure (absolute)35.487 bar
Steam temperature (≤ saturation = dry saturated)365.56 °C
Feedwater temperature110.00 °C
Blowdown fraction0 %
Gas inlet temperature521.11 °C
Gas exit temperature193.33 °C
Mean gas specific heat1.1304 kJ/(kg·K)
Heat retention factor99.000 %

Applying the formula below gives:

ResultValue
Heat to steam and blowdown23,175 kW
Gas flow227,439 kg/h
Steam per kg of gas0.13701 kg/kg

Open this example in the calculator and change any input.

Formula

\(W_g = \frac{W_s(h_s - h_{fw}) + bW_s(h_f - h_{fw})}{h_l\bar c_p(T_{g1} - T_{g2})}\)

Variables

Symbol Meaning SI unit
\(W_s\) Steam flow kg/s
\(p\) Steam pressure (absolute) Pa
\(T_s\) Steam temperature (≤ saturation = dry saturated) K
\(T_{fw}\) Feedwater temperature K
\(b\) Blowdown fraction -
\(T_{g1}\) Gas inlet temperature K
\(T_{g2}\) Gas exit temperature K
\(\bar c_p\) Mean gas specific heat J/(kg·K)
\(h_l\) Heat retention factor -
\(Q_s\) Heat to steam and blowdown W
\(W_g\) Gas flow kg/s
\(W_s/W_g\) Steam per kg of gas kg/kg

Method and standards

Energy balance.

Where it is used

  • HRSG acceptance tests.
  • Gas turbine exhaust flow checks.

Common mistakes

  • Mean c_p for the wrong gas analysis.
  • Neglecting blowdown and casing loss.

Assumptions and limits

  • Steady state; mean c_p over the range.
  • Feedwater must be liquid at the steam pressure, and the steam must carry more heat than the feedwater.

References

  • Ganapathy
  • Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
  • Q8.45a–b (HRSG performance testing; gas flow from an energy balance); IAPWS-IF97

Questions and answers

Why back-calculate gas flow?

Steam flow and temperatures are measured well; exhaust flow in a large duct is not, so the energy balance gives the most reliable gas flow.

What does Ganapathy's example give?

68,700 lb/h of 500 psig, 690 °F steam from 230 °F feedwater with gas cooling from 970 to 380 °F: about 501,000 lb/h of gas.

What next?

Simulate the HRSG at this flow and the actual pressure; compare the predicted steam and exit gas temperature with the measured ones.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.