Worked example
Example: 2 MW gas engine, 430 °C exhaust. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Engine electrical output | 2,000.0 kW |
| Electrical efficiency (on LHV) | 42.000 % |
| Exhaust flow | 11,000 kg/h |
| Exhaust temperature | 430.00 °C |
| Exhaust leaving the boiler | 180.00 °C |
| Exhaust specific heat | 1.1200 kJ/(kg·K) |
| Jacket and oil cooler heat | 1,100.0 kW |
| Steam pressure (absolute) | 9.0000 bar |
| Feedwater temperature | 90.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel input | 4,761.9 kW |
| Exhaust heat recovered | 855.56 kW |
| Steam from the exhaust | 1,285.4 kg/h |
| Total heat recovered | 1,955.6 kW |
| Overall CHP efficiency | 83.067 % |
Open this example in the calculator and change any input.
Formula
\(Q_f = \frac{P_e}{\eta_e}, \quad Q_{ex} = \dot m_gc_p(T_g - T_s), \quad \eta_{CHP} = \frac{P_e + Q_{ex} + Q_j}{Q_f}\)
\(\dot m_s = \frac{Q_{ex}}{h_g(p_s) - h_f(T_{fw})}, \quad Q_{th} = Q_{ex} + Q_j\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_e\) | Engine electrical output | W |
| \(\eta_e\) | Electrical efficiency | - |
| \(\dot m_g\) | Exhaust flow | kg/s |
| \(T_g\) | Exhaust temperature | K |
| \(T_s\) | Exhaust leaving the boiler | K |
| \(c_p\) | Exhaust specific heat | J/(kg·K) |
| \(Q_j\) | Jacket and oil cooler heat | W |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(T_{fw}\) | Feedwater temperature | K |
| \(Q_f\) | Fuel input | W |
| \(Q_{ex}\) | Exhaust heat recovered | W |
| \(\dot m_s\) | Steam from the exhaust | kg/s |
| \(Q_{th}\) | Total heat recovered | W |
| \(\eta_{CHP}\) | Overall CHP efficiency | - |
| \(h_g\), \(h_f\) | saturated steam enthalpy at \(p_s\) and saturated liquid enthalpy at \(T_{fw}\) (IF97) | J/kg |
Method and standards
Energy balance on the exhaust and the jacket circuit; steam and feedwater enthalpies from FireCAD's IAPWS-IF97.
Where it is used
- Gas engine CHP studies.
Common mistakes
- Counting heat that cannot be used.
- Mixing LHV and HHV efficiencies.
Assumptions and limits
- LHV basis throughout (electrical efficiency and fuel input).
- Saturated steam; feedwater enthalpy as saturated liquid at its temperature; no blowdown. Small effects.
- An evaporator alone can cool the exhaust only to about 10 K above the steam saturation temperature; a lower exit needs an economiser section (a warning appears).
- A warning appears when power plus recovered heat exceeds the fuel input.
References
- Energy balances (definitions)
- Steam and water properties from IAPWS-IF97
Questions and answers
How is engine heat split?
Roughly a third each to power, exhaust and cooling (jacket, oil, intercooler) in large gas engines.
What CHP efficiency is good?
80–90 % using both exhaust and jacket heat.
Why stop the exhaust at 160–180 °C?
Lower temperatures need costly surface and risk condensation.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.