Worked example
Example: 10 kg/s gas 300 → 120 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat source flow | 36,000 kg/h |
| Source specific heat | 1.1000 kJ/(kg·K) |
| Source in | 300.00 °C |
| Source out | 120.00 °C |
| Cooling (condensing) temperature | 35.000 °C |
| Share of Carnot achieved | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat taken from the source | 1,980.0 kW |
| Mean source temperature | 204.36 °C |
| Carnot efficiency between mean and cooling temperature | 35.467 % |
| Estimated ORC efficiency | 17.734 % |
| Estimated net power (the Carnot share covers all losses) | 351.13 kW |
Open this example in the calculator and change any input.
Formula
\(T_m = \frac{T_1 - T_2}{\ln(T_1/T_2)}, \quad \eta_C = 1 - \frac{T_c}{T_m}, \quad P = f\eta_C\,\dot mc_p(T_1 - T_2)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Heat source flow | kg/s |
| \(c_p\) | Source specific heat | J/(kg·K) |
| \(T_1\) | Source in | K |
| \(T_2\) | Source out | K |
| \(T_c\) | Cooling (condensing) temperature | K |
| \(f\) | Share of Carnot achieved | - |
| \(Q\) | Heat taken from the source | W |
| \(T_m\) | Mean source temperature | K |
| \(\eta_C\) | Carnot efficiency between mean and cooling temperature | - |
| \(\eta\) | Estimated ORC efficiency | - |
| \(P\) | Estimated net power | W |
Method and standards
Second-law estimate: Carnot efficiency between the source's thermodynamic mean temperature and the cooling temperature, times the share of Carnot you enter. That share stands for all real losses, pump and fan power included; nothing else is deducted.
Where it is used
- Screening ORC projects.
Common mistakes
- Using Carnot efficiency as achievable.
- Cooling the source below its dew point.
Assumptions and limits
- Constant specific heat.
- The source outlet temperature is not checked against the acid dew point of a flue gas or the ORC evaporator pinch: choose it with both in mind.
References
- Carnot efficiency between the source's thermodynamic mean temperature (T₁ − T₂)/ln(T₁/T₂) and the cooling temperature (second law)
Questions and answers
Why the log-mean source temperature?
A source cooled from T₁ to T₂ gives heat at that thermodynamic average for entropy purposes.
What share of Carnot is realistic?
40–60 % for good ORC plants.
Why not steam?
Below about 300 °C organic fluids make smaller, simpler turbines than steam.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.