Worked example
Example: Ganapathy: 50,000 lb/h, 1000 psia 900 °F, 200 psia vs 1 psia. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 22.680 t/h |
| Throttle pressure (absolute) | 68.948 bar |
| Throttle temperature | 482.22 °C |
| Process (back) pressure (absolute) | 13.790 bar |
| Condenser pressure (absolute) | 6.8948 kPa |
| Back-pressure expansion efficiency | 70.000 % |
| Condensing expansion efficiency | 75.000 % |
| Return condensate enthalpy | 0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power, back-pressure scheme | 1,955.7 kW |
| Process heat, back-pressure scheme | 19,270 kW |
| Energy output, back-pressure (power + heat) | 21,226 kW |
| Power, condensing scheme | 6,022.9 kW |
| Energy output ratio | 3.5242 |
Open this example in the calculator and change any input.
Formula
\(P_b = \dot m\eta_b(h_1 - h_{2s,b}), \quad Q_p = \dot m(h_2 - h_r), \quad P_c = \dot m\eta_c(h_1 - h_{2s,c})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Steam flow | kg/s |
| \(p_1\) | Throttle pressure (absolute) | Pa |
| \(T_1\) | Throttle temperature | K |
| \(p_b\) | Process (back) pressure (absolute) | Pa |
| \(p_c\) | Condenser pressure (absolute) | Pa |
| \(\eta_b\) | Back-pressure expansion efficiency | - |
| \(\eta_c\) | Condensing expansion efficiency | - |
| \(h_r\) | Return condensate enthalpy | J/kg |
| \(P_b\) | Power, back-pressure scheme | W |
| \(Q_p\) | Process heat, back-pressure scheme | W |
| \(E_b\) | Energy output, back-pressure (power + heat) | W |
| \(P_c\) | Power, condensing scheme | W |
| \(E_b/P_c\) | Energy output ratio | - |
Method and standards
Isentropic expansions with IF97 and expansion efficiencies.
Where it is used
- Cogeneration feasibility.
- Teaching energy utilisation.
Common mistakes
- Comparing heat and power as equal value without a price.
- Ignoring condensate return.
Assumptions and limits
- No extraction; generator losses not deducted.
- With \(h_r = 0\) (the default, Ganapathy's convention) the process heat includes the condensate's sensible heat, which inflates \(E_b\) and the ratio; enter the return condensate enthalpy for a realistic comparison.
- A warning appears when the condensing exhaust is wetter than about 0.88 dryness.
- The throttle must be superheated (or supercritical) steam; a throttle state below saturation is rejected.
References
- Ganapathy
- Steam Plant Calculations Manual
- 2nd ed. (Marcel Dekker, 1993)
- Q5.02b (comparison of energy utilisation)
- Steam and water properties from IAPWS-IF97
Questions and answers
Why does cogeneration use energy better?
The back-pressure exhaust's latent heat goes to process instead of the condenser.
Is power output lower?
Yes: the back-pressure turbine expands over a smaller pressure ratio.
Why is condensate enthalpy an input?
Process heat is the exhaust enthalpy less what returns as condensate; Ganapathy counts it all.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.