FireCADCalc

Regenerative Rankine Cycle (Open Feed Heater)

Thermal efficiency of a Rankine cycle with one open feedwater heater (deaerator), the bled-steam fraction and net work, from the steam and heater conditions (IAPWS-IF97).

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Steam turbineDeaerator and feedwater system

Inputs

Examples: Ideal: 66 bar(a) / 485 °C, heater 4 bar(a), 0.1 bar(a)Real: same, turbine 85 %, pump 75 %150 bar(a) / 535 °C, heater 10 bar(a), 0.08 bar(a), 88 % / 80 %

Results

Exhaust dryness 81.8 %: below about 88 % the last-stage blades erode; raise the inlet temperature or add reheat.

Cycle thermal efficiency40.980%
Steam bled to the heater, per kg of main steam16.504%
Net work per kg of main steam1,134.5kJ/kg
Specific steam consumption (per kWh of net shaft work)3.1733kg/kWh
Heat added in the boiler2,768.3kJ/kg
Turbine exhaust dryness81.803%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ideal: 66 bar(a) / 485 °C, heater 4 bar(a), 0.1 bar(a). The inputs, in the units selected above:

InputValue
Inlet steam pressure (absolute)66.000 bar
Inlet steam conditionSuperheated at the temperature below
Inlet steam temperature (superheated only)485.00 °C
Feedwater heater (bleed) pressure (absolute)4.0000 bar
Condenser pressure (absolute)10.000 kPa
Turbine isentropic efficiency (each section)100.00 %
Pump isentropic efficiency (condensate and feed pumps)100.00 %

Applying the formula below gives:

ResultValue
Cycle thermal efficiency40.980 %
Steam bled to the heater, per kg of main steam16.504 %
Net work per kg of main steam1,134.5 kJ/kg
Specific steam consumption (per kWh of net shaft work)3.1733 kg/kWh
Heat added in the boiler2,768.3 kJ/kg
Turbine exhaust dryness81.803 %

Open this example in the calculator and change any input.

Formula

\(y = \frac{h_f(p_h) - h_{p1}}{h_x - h_{p1}} \qquad w_t = (h_1 - h_x) + (1 - y)(h_x - h_4)\)

\(h_x = h_1 - \eta_t\left[h_1 - h(p_h, s_1)\right] \qquad h_4 = h_x - \eta_t\left[h_x - h(p_2, s_x)\right]\)

\(h_{p1} = h_f(p_2) + w_{p1},\ w_{p1} = \frac{h(p_h, s_f) - h_f(p_2)}{\eta_p} \qquad h_{p2} = h_f(p_h) + w_{p2},\ w_{p2} = \frac{h(p_1, s_f) - h_f(p_h)}{\eta_p}\)

\(w_p = (1 - y)\,w_{p1} + w_{p2} \qquad q_{in} = h_1 - h_{p2} \qquad \eta_{th} = \frac{w_t - w_p}{q_{in}} \qquad SSC = \frac{1}{w_t - w_p}\)

Variables

Symbol Meaning SI unit
\(p_1\) main steam pressure, absolute Pa
\(\text{state}\) dry saturated or superheated steam –
\(T_1\) main steam temperature K
\(p_h\) feed heater (bleed) pressure, absolute Pa
\(p_2\) condenser pressure, absolute Pa
\(\eta_t\) turbine isentropic efficiency, each section –
\(\eta_p\) pump isentropic efficiency (condensate and feed pumps) –
\(\eta_{th}\) cycle thermal efficiency –
\(y\) bled steam per kg of main steam –
\(w_{net}\) net work per kg of main steam J/kg
\(SSC\) specific steam consumption kg/J
\(q_{in}\) heat added in the boiler J/kg
\(x_4\) turbine exhaust dryness –
\(w_t\), \(w_p\) turbine and pump work J/kg
\(w_{p1}\), \(w_{p2}\) condensate pump and feed pump work J/kg
\(h_1\), \(h_x\), \(h_4\) main steam, bleed and exhaust enthalpies J/kg
\(h_{p1}\), \(h_{p2}\) enthalpy after condensate pump and after feed pump J/kg
\(h_f\) saturated liquid enthalpy at heater pressure J/kg
\(s_x\), \(s_f\) entropy at the bleed point, and of the saturated liquid entering each pump J/(kg·K)

Method and standards

Rankine cycle with one open (mixing) feedwater heater leaving saturated liquid at heater pressure; isentropic efficiencies on both turbine sections and both pumps; states by FireCAD's IAPWS-IF97.

Where it is used

  • Choosing the deaerator pressure of a cogeneration or power plant.
  • Teaching and checking regenerative feed heating.
  • First heat balances before detailed design.

Common mistakes

  • Taking the bled fraction as a share of the condenser flow instead of the main steam.
  • Forgetting the second pump after the open heater.
  • Using gauge deaerator pressure.

Assumptions and limits

  • One open heater, no closed heaters, no reheat; no pressure drops; heater outlet saturated.
  • The same η_t is applied to each turbine section, the LP section starting from the actual bleed state. Because of the reheat-factor effect the whole turbine is then slightly more efficient than η_t, so this cycle is not exactly like for like with the simple Rankine page at the same η_t.
  • SSC is per kWh of net shaft work, before generator losses.

References

  • IAPWS R7-97(2012) IF97
  • first and second laws of thermodynamics

Questions and answers

How much does one feed heater gain?

With 66 bar(a) and 485 °C steam, a heater at 4 bar(a) and a 0.1 bar(a) condenser, the ideal cycle rises from 38.5 % to 41.0 %, bleeding 16.5 % of the steam.

Why does bleeding steam raise efficiency?

The bled steam's latent heat warms the feedwater instead of going to the condenser, so the boiler adds heat at a higher average temperature.

Is an open feed heater a deaerator?

In most plants, yes: the deaerator is the open (direct-contact) heater. Closed heaters are calculated with the feedwater heater extraction calculator.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.