Worked example
Example: 67 bar, 430 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 60.000 t/h |
| Parallel tubes | 48.000 - |
| Tube bore | 38.100 mm |
| Steam pressure (absolute) | 67.000 bar |
| Steam temperature | 430.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam density | 22.408 kg/m³ |
| Mass flux | 304.56 kg/(m²·s) |
| Steam velocity | 13.591 m/s |
Open this example in the calculator and change any input.
Formula
\(G = \frac{\dot m_s}{n \pi d_i^2/4}, \quad v = \frac{G}{\rho}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | Steam flow | kg/s |
| \(n\) | Parallel tubes | - |
| \(d_i\) | Tube bore | m |
| \(p\) | Steam pressure (absolute) | Pa |
| \(T\) | Steam temperature | K |
| \(\rho\) | Steam density | kg/m³ |
| \(G\) | Mass flux | kg/(m²·s) |
| \(v\) | Steam velocity | m/s |
Method and standards
Continuity: mass flux is the steam flow over the total bore area of the parallel tubes; velocity is the mass flux over the IAPWS-IF97 steam density at the pressure and temperature entered.
Where it is used
- Superheater design checks.
- Overheating investigations.
Common mistakes
- Counting all tubes instead of parallel paths.
Assumptions and limits
- Uniform distribution between the tubes; whole number of tubes.
- One steam state: the density changes along a superheater, so enter the state where you want the velocity (the outlet, hottest steam, gives the highest velocity; the inlet the lowest).
- Notes appear for zero flow and for a velocity outside 10–25 m/s.
References
- Continuity G = ṁ/(n π d²/4); steam density from IAPWS-IF97
Questions and answers
Why mass flux?
It sets the steam-side heat-transfer coefficient that cools the tube.
Start-up?
With little steam flow the tubes are poorly cooled: limit firing until flow is established.
Velocity range?
Typically 10–25 m/s in superheaters; check with your design practice.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.