Worked example
Example: 120 t/h air, 15 to 50 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air flow | 120.00 t/h |
| Air in | 15.000 °C |
| Air out | 50.000 °C |
| Air specific heat | 1.0060 kJ/(kg·K) |
| Heating steam pressure (absolute) | 4.0000 bar |
| Heating steam | Dry saturated |
| Heating steam temperature (superheated only) | 200.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air heating duty | 1,173.7 kW |
| Latent heat at steam pressure | 2,133.3 kJ/kg |
| Steam condensed | 1,980.6 kg/h |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_a c_{p,a}(T_2 - T_1), \quad \dot m_s = \frac{\dot Q}{h_s - h_f(p_s)}, \quad h_{fg} = h_g - h_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_a\) | Air flow | kg/s |
| \(T_1\) | Air in | K |
| \(T_2\) | Air out | K |
| \(c_{p,a}\) | Air specific heat | J/(kg·K) |
| \(p_s\) | Heating steam pressure (absolute) | Pa |
| \(\dot Q\) | Air heating duty | W |
| \(h_{fg}\) | Latent heat at steam pressure | J/kg |
| \(\dot m_s\) | Steam condensed | kg/s |
| \(\text{state}\) | Heating steam: dry saturated or superheated | - |
| \(T_s\) | Heating steam temperature (superheated only) | K |
| \(h_s\), \(h_f\), \(h_g\) | steam supplied, saturated liquid and saturated vapour enthalpies (IF97) | J/kg |
Method and standards
Energy balance: the air heating duty is supplied by steam condensing to saturated liquid at the steam pressure, so each kilogram gives h_s − h_f (the latent heat h_fg = h_g − h_f for dry saturated steam, more when superheated). IAPWS-IF97 properties.
Where it is used
- SCAPH sizing.
- Winter operation.
Common mistakes
- Gauge pressure for latent heat.
Assumptions and limits
- Saturated condensate out, no subcooling and no heat loss.
- Heating steam dry saturated or superheated as chosen; wet steam gives less heat per kg and needs more steam than shown.
- One air specific heat (default dry air near ambient); humid air is 1–2 % higher.
- A note appears when the air leaves within 5 K of the steam temperature.
References
- Energy balance with IAPWS-IF97 latent heat (saturated condensate)
Questions and answers
Why heat air with steam?
To keep the air heater cold end above the acid dew point when air is cold or load is low.
Is the steam wasted?
Partly recovered: hotter air reaches the furnace. The net cost is small compared with corrosion damage.
Which steam?
Low-pressure extraction or exhaust steam.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.