Reheater Duty (Cold to Hot Reheat)

Heat absorbed by a boiler reheater from the reheat steam flow and the cold and hot reheat pressures and temperatures, with the pressure drop (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerSteam turbine

Inputs

Examples: 520 t/h, 42 bar(a) 330 °C to 39 bar(a) 540 °C250 t/h, 30 bar(a) 320 °C to 28 bar(a) 535 °C1500 t/h, 45 bar(a) 340 °C to 42 bar(a) 565 °C

Results

Reheater duty72.399MW
Enthalpy rise501.23kJ/kg
Pressure drop, share of inlet pressure7.1429%
Cold reheat enthalpy3,037.1kJ/kg
Hot reheat enthalpy3,538.3kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 520 t/h, 42 bar(a) 330 °C to 39 bar(a) 540 °C. The inputs, in the units selected above:

InputValue
Reheat steam flow520.00 t/h
Cold reheat pressure (absolute)42.000 bar
Cold reheat temperature330.00 °C
Hot reheat pressure (absolute)39.000 bar
Hot reheat temperature540.00 °C

Applying the formula below gives:

ResultValue
Reheater duty72.399 MW
Enthalpy rise501.23 kJ/kg
Pressure drop, share of inlet pressure7.1429 %
Cold reheat enthalpy3,037.1 kJ/kg
Hot reheat enthalpy3,538.3 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot Q_{rh} = \dot m_{rh}\,(h_{hrh} - h_{crh}) \qquad \frac{\Delta p}{p} = \frac{p_{crh} - p_{hrh}}{p_{crh}}\)

Variables

Symbol Meaning SI unit
\(\dot m_{rh}\) reheat steam flow kg/s
\(p_{crh}\) cold reheat pressure Pa
\(T_{crh}\) cold reheat temperature K
\(p_{hrh}\) hot reheat pressure Pa
\(T_{hrh}\) hot reheat temperature K
\(\dot Q_{rh}\) reheater duty W
\(\Delta h\) enthalpy rise J/kg
\(\Delta p / p\) pressure drop share –
\(h_{crh}\) cold reheat enthalpy J/kg
\(h_{hrh}\) hot reheat enthalpy J/kg

Method and standards

Steam-side energy balance with IAPWS-IF97 superheated steam enthalpies.

Where it is used

  • Utility boiler heat balance.
  • Performance tests.
  • Reheater surface checks.

Common mistakes

  • Using main steam flow (reheat flow is lower by extractions and leakages).
  • Forgetting spray water.
  • Mixing gauge and absolute pressures.

Assumptions and limits

  • Steady state; flow includes any spray added before the reheater. The duty then treats the spray as if it entered at the cold reheat enthalpy; spray water injected at feedwater enthalpy needs the extra heat m_spray (h_crh − h_spray) added.
  • A note appears when the pressure drop is above 10 % of the cold reheat pressure.

References

  • IAPWS-IF97

Questions and answers

What does a reheater take for 520 t/h from 42 bar 330 °C to 39 bar 540 °C?

72.4 MW: 501 kJ/kg on a 7.1 % pressure drop.

Why does reheater pressure drop matter?

Every bar lost lowers the work of the IP and LP turbine.

Is reheat spray included?

Add spray water to the flow if it is injected before the reheater.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.