Air Heater Leakage from O₂ Readings

Air leakage of a regenerative or tubular air heater from the flue gas O₂ before and after it, and the gas outlet temperature corrected for no leakage.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperASME PTC 4 (fired steam generators)BoilerEconomiser and air preheaterFan and blower

Inputs

Examples: Regenerative heater: O2 3.5 to 5.0 %Tubular heater, small leak: 4.0 to 4.4 %Worn seals: 3.0 to 6.5 %

About 30 kg/kmol for coal and oil.
Mass share of moisture in the wet gas. Leave 0 to apply the dry-gas leakage ratio directly (the older approximation); 0.05–0.10 is typical for coal.

Results

The no-leakage correction uses the leakage per kg of dry gas; enter the gas moisture to apply it per kg of wet gas (a correction about 5–10 % smaller).

Leakage, kg of air per kg of gas entering (approx., dry)2.3336%
Leakage, kmol of air per kmol of dry gas entering2.4169%
Gas temperature leaving, corrected for no leakage152.69°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Regenerative heater: O2 3.5 to 5.0 %. The inputs, in the units selected above:

InputValue
O₂ in dry flue gas entering the air heater3.5000 %
O₂ in dry flue gas leaving the air heater5.0000 %
Molar mass of the dry flue gas30.000 kg/kmol
Measured gas temperature leaving the air heater140.00 °C
Air temperature entering the air heater30.000 °C
Specific heat of air1.0100 kJ/(kg·K)
Specific heat of flue gas1.0500 kJ/(kg·K)
Water vapour in the flue gas entering, by mass0 %

Applying the formula below gives:

ResultValue
Leakage, kg of air per kg of gas entering (approx., dry)9.0803 %
Leakage, kmol of air per kmol of dry gas entering9.4044 %
Gas temperature leaving, corrected for no leakage149.61 °C

Open this example in the calculator and change any input.

Formula

\(L_n = \frac{O_{2,2} - O_{2,1}}{0.2095 - O_{2,2}} \qquad L_m = L_n\,\frac{M_a}{M_g}\)

\(T_{g,nl} = T_{g,2} + L_m\,(1 - w_g)\,\frac{c_{p,a}}{c_{p,g}}\,(T_{g,2} - T_{a,1})\)

Variables

Symbol Meaning SI unit
\(O_{2,1}\) O₂ in dry flue gas entering the air heater –
\(O_{2,2}\) O₂ in dry flue gas leaving the air heater –
\(M_g\) molar mass of dry flue gas kg/kmol
\(M_a\) molar mass of dry air, 28.96 kg/kmol kg/kmol
\(T_{g,2}\) measured gas temperature leaving K
\(T_{a,1}\) air temperature entering K
\(c_{p,a}\) specific heat of air J/(kg·K)
\(c_{p,g}\) specific heat of flue gas J/(kg·K)
\(L_m\) leakage, kg of air per kg of dry gas entering –
\(w_g\) water vapour in the wet flue gas entering, mass fraction –
\(L_n\) leakage, kmol of air per kmol of dry gas entering –
\(T_{g,nl}\) gas outlet temperature corrected to no leakage K

Method and standards

Leakage from an oxygen balance on dry flue gas, the approach of ASME PTC 4.3 (Air Heaters), and the gas outlet temperature corrected to no leakage by a mixing balance. The molar leakage is converted to mass with the ratio of the molar masses of dry air and dry flue gas that you enter, rather than a fixed factor.

Where it is used

  • Routine monitoring of rotary (Ljungström) and tubular air heaters in power and process boilers.
  • Deciding when to replace seals or plug tubes.
  • Checking the ID fan margin: leakage air is extra gas for the ID fan to move.

Common mistakes

  • Comparing O₂ from a single probe at each side: stratification in large ducts needs a grid.
  • Mixing wet and dry O₂ readings.
  • Taking O₂ at the air heater inlet from the economiser outlet probe when there is in-leakage in between.

Assumptions and limits

  • All the O₂ rise is air leaking from the air side; no other in-leakage between the probes.
  • Mass leakage on a dry basis with a fixed dry gas molar mass. The mixing correction applies per kg of wet gas, so the dry ratio is multiplied by \((1 - w_g)\); with \(w_g = 0\) (the default) the correction is the older dry approximation, about 5–10 % too large.

References

  • ASME PTC 4.3-2017 Air Heaters (leakage and no-leakage gas temperature)

Questions and answers

How do I calculate air heater leakage from O₂?

The rise in O₂ across the heater is air leaking from the air side into the gas. O₂ rising from 3.5 to 5.0 % dry means 9.4 kmol of air per 100 kmol of gas, about 9.1 % by mass with a dry gas molar mass of 30.

What leakage is normal?

Tubular air heaters leak little when sound, about 1–3 %, more as tubes corrode. Regenerative (rotary) heaters typically run at 6–12 %, rising as seals wear.

Why correct the gas outlet temperature?

Leakage air mixes with the gas and cools it, so the measured outlet looks good while heat transfer may be falling. The no-leakage temperature is what the gas would be without that air; it is the fair figure for performance.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.