Worked example
Example: Coal, 2.5 % S, 2 % conversion. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water vapour in flue gas | 10.000 % |
| Flue gas pressure (absolute) | 1.0132 bar |
| SO₃ source | Estimate from fuel sulphur |
| Sulphur in fuel (as fired) | 2.5000 % |
| Specific wet flue gas volume | 10.000 Nm³/kg |
| SO₂ → SO₃ conversion | 2.0000 % |
| SO₃ in flue gas | 0 ppm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Acid dew point | 150.14 °C |
| SO₃ used in the correlation | 0.003496 % |
| SO₂ from the fuel sulphur | 0.17478 % |
| Partial pressure of water vapour | 0.10132 bar |
| Partial pressure of SO₃ | 3.5419e-05 bar |
Open this example in the calculator and change any input.
Formula
Verhoff and Banchero (1974), partial pressures in mmHg:
\(\frac{1000}{T_{dp}} = 2.276 - 0.02943\,\ln p_{H_2O} - 0.0858\,\ln p_{SO_3} + 0.0062\,\ln p_{H_2O}\,\ln p_{SO_3}\)
\(p_{H_2O} = y_{H_2O}\,p \qquad p_{SO_3} = y_{SO_3}\,p\)
SO₃ estimated from the fuel: sulphur burns to SO₂ one mole per mole, a fraction \(f_{SO_3}\) oxidises further:
\(y_{SO_2} = \frac{S / M_S \cdot V_m}{V_g} \qquad y_{SO_3} = f_{SO_3}\, y_{SO_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{dp}\) | sulphuric acid dew point | K |
| \(y_{H_2O}\) | water vapour in wet flue gas, volume fraction | – |
| \(p\) | absolute flue gas pressure | Pa |
| \(\text{mode}\) | SO₃ estimated from fuel sulphur, or entered | – |
| \(S\) | sulphur in the fuel as fired, mass fraction | – |
| \(M_S\) | molar mass of sulphur, 32.06 | kg/kmol |
| \(V_m\) | molar volume at 0 °C and 101.325 kPa, 22.414 | Nm³/kmol |
| \(V_g\) | wet flue gas volume per kg fuel, at 0 °C and 101.325 kPa | Nm³/kg |
| \(f_{SO_3}\) | fraction of SO₂ converted to SO₃ | – |
| \(y_{SO_2}\) | SO₂ in wet flue gas, volume fraction | – |
| \(y_{SO_3,in}\) | SO₃ entered directly, volume fraction | – |
| \(y_{SO_3}\) | SO₃ used in the correlation | – |
| \(p_{H_2O}\) | partial pressure of water vapour (converted to mmHg in the correlation) | Pa |
| \(p_{SO_3}\) | partial pressure of SO₃ (converted to mmHg in the correlation) | Pa |
Method and standards
The Verhoff–Banchero correlation is widely used in boiler and air-heater design practice. It was fitted to measured dew points with partial pressures in mmHg; the calculator converts the SI partial pressures to mmHg (1 mmHg = 133.322 Pa) before taking the logarithms. Entering the pressures in atmospheres instead, a common mistake, gives dew points about 125 K too low.
Where it is used
- Setting the minimum flue gas exit temperature of boilers burning coal, oil or sulphur-bearing gas.
- Choosing the cold-end metal temperature of economisers and air preheaters, and steam coil air heaters.
- Stack and duct material selection and insulation design.
Common mistakes
- Comparing the dew point with the flue gas temperature instead of the coldest metal temperature.
- Assuming all sulphur goes to SO₃: only a few per cent does; the SO₃ share sets the dew point.
- Ignoring part load, when the gas leaves colder and the air heater cold end is coldest.
Assumptions and limits
- Fitted range roughly 5–15 % H₂O and 1–100 ppm SO₃; outside it the result is indicative.
- The SO₂ estimate assumes all fuel sulphur reaches the gas (no sulphur retained in ash or sorbent). For fluidised beds with limestone, enter the measured SO₂ or SO₃ directly.
- A separate water dew point governs when SO₃ is nil.
References
- Verhoff & Banchero (1974)
- ASME PTC 4.3 air heaters
Questions and answers
Why does the dew point depend so weakly on water but strongly on SO₃?
Per doubling the two are similar: at 10 % water and 15 ppm SO₃, doubling SO₃ raises the dew point about 7 K and doubling water also about 7 K. But SO₃ varies over orders of magnitude (1 to 50 ppm moves the dew point about 38 K), while water in flue gas stays within about 5–15 % (about 11 K).
How much SO₂ converts to SO₃?
Typically 1–3 % in coal-fired boilers, more with vanadium-bearing heavy fuel oil (2–5 %) and across SCR catalysts (0.5–1.5 % additional). It is the least certain input; try the range.
What metal temperature should I design for?
Keep the cold-end minimum metal temperature at or above the acid dew point plus a margin (commonly 10–15 K). Corrosion rate peaks 20–40 K below the dew point, not at it.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.